Enter Configuration
Exit and Save Configuration
Ì$+;Î
DATA FORMAT
Ì$-?Î
56
C
HARACTER
R
EPLACEMENT
disable character replacement
ÌEO0mÎ
This parameter allows up to three characters to be replaced from the barcode read. These
substitutions are stored in memory. To define each character replacement:
c
Read one of the following character replacement codes:
first character replacement
ÌEO1pÎ
second character replacement
ÌEO2sÎ
third character replacement
ÌEO3vÎ
d
From the Code Identifier Table in Appendix
B
, read the Code Identifier for the desired code
family.
0
= character replacement will be effective for all code families.
e
From the Hex/Numeric Table read two characters corresponding to the Hex value (
00
-
FE
) which
identifies the character to be replaced.
For Wedge and USB-KBD interfaces, it is also possible to
read the
Special Key(s)
on page 53.
f
From the Hex/Numeric Table read two characters corresponding to the Hex value (
00
-
FE
) which
identifies the new character to replace. For Wedge and USB-KBD interfaces, it is also possible to
read the
Special Key(s)
on page 53.
FF
= the character to be replaced will be substituted with no character, that is, it will be
removed from the code.
Summary of Contents for DelfiScan M80
Page 1: ...DelfiScan M80 Programming Manual...
Page 3: ......
Page 14: ...INSTALLATION 7 2 8 PEN EMULATION CONNECTION 2 9 SINGLE READER LAYOUT...
Page 22: ...CONFIGURATION 15 WEDGE CONTINUED DIGITAL TERMINALS VT2xx VT3xx VT4xx CP512 u...
Page 162: ...CODE IDENTIFIER TABLE tu RSS Limited RSS 14 Linear and Stacked vw uv...