REFERENCES
133
example, if codes must be read from a location where there is no radio network. Upon
returning to the system working area, this mode requires reading the
Start Normal Batch
Transmission
barcode to successively transmit the list of stored codes to the base station.
The FIFO management assures that the first code read will be the first code to be
transmitted to the base station.
The
Delete Batch Data
barcode allows canceling all barcode data stored in the reader.
Automatic batch mode allows codes to be stored in the reader on a FIFO basis whenever
the reader is out of radio range. In this case radio communication is not suspended and
transmission is attempted after each code read. If transmission cannot be successfully
completed, then the code is added to the list. When the reader returns in range,
transmission of the codes to the base station resumes automatically, according to the
selected communication protocol, upon simply pressing and releasing the trigger or by
successfully reading a new code.