3.7 INTERNAL HARDWARE SERVICING
The P.T.S. is designed with self-test and self-monitoring features to warn of failures (see Table 2.1).
Although it is very unlikely, modes of failure may also occur that cause erratic operation and/or illegible
displays and may or may not trigger alarms. If the maintenance, calibration, and troubleshooting procedures
described above do not restore normal operation, contact Delfi for service advice.
CAUTION: Do not attempt to disassemble or open the enclosure of your P.T.S. unit. The P.T.S. is not
designed to be disassembled and serviced by anyone other than Delfi staff. Disassembly and
attempted service by anyone other than Delfi staff poses a risk of electric shock, damage to the unit,
and injury to the patient and will void all warranties. Internal parts in the P.T.S. can only be serviced
at the factory by Delfi staff. Please contact Delfi if you have problems with your P.T.S. unit that
cannot be resolved by following the maintenance and troubleshooting procedures described above.
3.8 WARNINGS, CAUTIONS, LABELS, and SYMBOL DEFINITIONS
Type B Medical Equipment
Earth ground
Refer to operator and maintenance manual
Alternating Current
Electrical hazard: Dangerous voltage
Direct current
Conformity marking of the Council of the European Community
cTUVus: Medical Equipment with respect to electrical shock, fire and mechanical hazards
and electromagnetic compatability only in accordance with CAN/CSA – C22.2 No.601.1-
M90, and UL 2601-1
Authorized representative in the European Community
Manufacturer name and adress
Figure 3.1: Labels
ATTENTION:
THIS UNIT MUST BE CHARGED AT LEAST 8
HOURS BEFORE INITIAL USE, CALIBRATION,
OR FUNCTIONAL CHECK. REFER TO
OPERATOR'S MANUAL FOR CHARGING
INSTRUCTIONS. REMOVE AND DISCARD
THIS LABEL WHEN COMPLETE.
U.S. PATENTS:
FOREIGN PATENTS
6,213,939; 5,931,853; 5,649,954
4,469,099; PAT. PEND. and
MADE IN CANADA
Delfi
ATTENTION
: FOR USE BY TRAINED
PERSONNEL ONLY.
DANGER: EXPLOSION HAZARD. DO
NOT USE IN THE PRESENC E OF FLAM-
MABLE ANESTHETIC S OR GASES.
C AUTION: RISK OF ELEC TRIC SHOC K.
DO NOT DISASSEMBLE. TO BE SERVI-
C ED BY QUALIFIED PERSONNEL ONLY.
REF 9-2100-001
FOR USE WITH REF 4 -2 10 0-01 3
DELFI POWER SUPPLY ONLY.
SN YYYY-NNNN
De lfi Me d ic a l Inno va tio ns Inc .
Vancouver, BC Canada
800.933.3022
0197
Delfi
www.d e lf im e d ic a l. c o m
Delfi Med ic a l Innovations Inc .
Vancouver, BC Canada
800.933.3022
FOR USE O NLY WITH De lfi 9-2100 SERIES
P.T.S. PORTABLE TO URNIQUET SYSTEMS
DO NOT INCINERATE.
STO RE AT ROO M TEMPERATURE O R CO OLER.
REC YC LE / DISPOSE AT PROPER FAC ILITY
REF 4-2100-017
NIMH BATTERY
De lfi Me d ic a l Inno va tio ns Inc .
Va nc o uve r BC C a na d a
8 00-933-3022
Delfi
DANG ER: FIRE HAZARD. USE
DELFI REPLACEMENT BATTERY
REF 4-2100-017 O NLY.
CAUTION:
KEEP DRY.
DO NOT IMMERSE.
SN YYYY-XXXX
EC