V0606, 8.12
Pressure correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PC =
Percentage of calculated tonnages which actually controls the pressure valve.
Clamping correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC =
The position of the beam at which the plate is clamped, is calculated. In order to have a
firm clamped plate it is possible to offset the calculated pinch point with the value here
programmed. A positive value will result in a deeper position, a negative value in a
higher position of the beam.
X-reference correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C1 =
When the actual, mechanical X-axis position is not corresponding with the displayed
value than is it possible to correct the position with this parameter. Program the calcu-
lated difference.
Example:
- When the programmed and displayed value = 250 and the actual, mechanical position
value = 252 the XR parameter = -2.
- When the programmed and displayed value = 250 and the actual, mechanical position
value = 248 the XR parameter = +2.
X2-reference correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C2
Same function as the previous parameter but now for the X2-axis.
Part support retour speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PR=
Return speed of the part support after a bending. The speed value is programmed as a
percentage of the maximum speed.
Only available when there is a part support on the system.
Part support extra angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PE=
Extra angle for the part support unit. This angle value is added to the part support angle
position at the end of decompression. So while the pressbeam moves up to its upper dead
point, the part support moves to a new position. When the beam has reached upper dead
point, the part support will move back to zero.
Only available when there is a part support on the system.
Intermediate X for Z-movement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XS=
Temporary safe value for the X-axis, to avoid collision as a result of movement along the
Z-axis. With this parameter a standard safety zone for the X-axis is defined, which is
valid for all programs. The value 0 disables this functionality. This parameter should not
be confused with the parameter ‘X-safety’ of each die.
This parameter is especially useful when several dies of different sizes are placed on the
machine. In that situation, this intermediate X-value should be larger than the safety zone
Summary of Contents for DA-65W
Page 1: ...Delem Manual version V0606 DA 65W Reference Manual Operation of Version V2 ...
Page 6: ...V0606 0 6 ...
Page 50: ...V0606 2 30 ...
Page 75: ...Delem V0606 5 5 5 e ...
Page 78: ...V0606 5 8 ...
Page 86: ...V0606 6 8 6 i ...
Page 100: ...V0606 6 22 ...
Page 144: ...V0606 10 6 Functions screen 10 d Graphical visualisation 10 e ...