5.2
5.2
5.2
5.2 Meter housing
Meter housing
Meter housing
Meter housing
The wings of the valve guide must be placed
in the notches that have knobs. Make sure
not to mix them up with the other notches.
The valve guide must be locked to the cup.
When you have assembled the meter cup,
pour some water in it and check that it does
not leak.
Hold up the valve arm inside the meter
housing when the electronic unit with the
gauge is put back in place. Make sure the
cables are not jammed.
5.3
5.3
5.3
5.3 Spoiler
Spoiler
Spoiler
Spoiler
5 moulded legs
Three of the five legs are moulded close to
each other. See adjoining figure! When instal-
ling the spoiler plate notice that two of these
three legs must be placed between the two bars
moulded inside the housing. This is vital for a
proper function. If the spoiler plate is installed
correctly non of the legs should touch the meter
cup locking clip.
4 moulded legs
The plate with only four legs moulded under-
neath must be placed with no leg between the
two bars because of the risk of blocking the
weight cell.
5.4
5.4
5.4
5.4 Valve seal
Valve seal
Valve seal
Valve seal
(A)Article number up
Make sure not to mount the seal upside
21
61
00
DeLaval milk meter MM15
DeLaval milk meter MM15
DeLaval milk meter MM15
DeLaval milk meter MM15
161 Preventive maintenance
5 (9)
© DeLaval 2012.All rights reserved.
Printout from Memoviewer 11/6/2012.