OPERATION
• Press the push-button to flush.
• Direct flush: instant flush flow rate determined by the dimensions
of the supply pipes and the dynamic pressure available.
• Valve shuts-off automatically after ~7 sec.
• Not suitable for children’s small WC pans.
INSTALLATION
• Recommended dynamic pressure: 1 - 3 bar (minimum1 bar).
• Always observe the direction of the water flow, as indicated
on the body of the valve.
• Height of the push-button in relation to the pan: 500mm minimum.
• Length of flush tube: 400mm minimum for the straight section;
elbow radius 50mm minimum.
TEMPOCHASSE Valve (Fig. A):
• Connect the stopcock
a
(order separately) to the water supply.
• Fit the valve
b
onto the flush tube
c
(order separately).
• Connect the valve
b
to the stopcock
a
and operate the valve
b
several times to stabilise the time flow.
TEMPOCHASSE Kit for Cross Wall Installation (Fig. B, C):
• Drill hole: 21mm for the control
h
and 5.5 mm for the anti-rotating
pin
i
.
• Insert the control
h
into the wall. Tighten the nut
g
in place
with the washer. If necessary cut the control
h
and the rod
k
(by the same amount x) to the desired length.
• Using the screw
e
, allow a gap of 1mm between the rod
k
and the valve head
b
.
• Tighten the nut
f
.
• Connect the stopcock
a
to the water supply.
• Fit the valve
b
onto the flush tube
c
(order separately).
• Fit 2 mounting collars
d
(not supplied), one upstream of the
stopcock
a
and one downstream of the valve
b
.
Fix the mounting
collars
d
to the wall (using rawl plugs that are suitable for the type
of wall material).
• Connect the valve
b
to the stopcock
a
and press the push-button
j
several times to stabilise the time flow.