2
EC–AG
Installation & Operations Manual
of sprinklers or drainage spouts. Allow sufficient access for
maintenance and all tubing and electrical wires. Ozone Generator
should be installed at least (not less than) one foot above the
maximum water level. See Section 2D-2, Ozone Gas Line, for
plumbing instructions based on mounting location.
2B. Wall Mounting
a. Refer to Figure 1 to mark the locations for the two mounting
screws.
b. Install screws (or other hardware appropriate for mounting
surface) through the two mounting holes built in to the base of
the EC–AG ozone system.
2C. Electrical
2C-1. Main Power
Connect the Ozone Generator to the pool timing clock so that the
Ozone Generator operates simultaneously with the pool pump. The
circuit must be protected by a ground-fault circuit interrupter (GFCI)
installed in accordance to electrical code. Refer to the IMPORTANT
SAFETY INSTRUCTIONS at the beginning of this manual for
important wiring information. If the EC–AG power cord comes with
a built-in receptacle and the pump is equipped with a standard plug
(NEMA 5-15P), the pump may be plugged in on top of the EC–AG
cord (pump current must not exceed 15A). Plug must be protected
from moisture.
2D. Plumbing
Ozone gas is introduced to the pool circulation line using a venturi
Injector. Suction developed by the venturi allows the Ozone
Figure 1: Wall Mount
8.0"