IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS.

•  Read this manual completely before attempting installation. 
•  All permanent electrical connections should be made by a qualified  

 

 electrician. 
•  Connect to a grounding type receptacle only. If the ozone generator    
  electrical connection is to be attached to the pool controls, be sure  

 

  the pool controls are protected by a Ground Fault Circuit Interrupter    
  (G.F.C.I.). If the ozone generator is connected to an independent  

 

  electrical supply, then a G.F.C.I. must be installed between the ozone    
  generator and the electrical supply. 
•  Do not bury cord. 
•  Warning – To reduce the risk of electrical shock, replace damaged cord  
 immediately. 
•  Install at least 5 feet (1.5 meters) from wall of pool. Install ozone  

 

  generator no less than one (1) foot above maximum water level to  

 

  prevent water from contacting electrical equipment. Install in    

 

  accordance with the installation instructions. 
•  Follow all applicable electrical codes. 
•  Electric shock hazard. Be sure to turn power OFF and disconnect from  
  power source before any service work is performed. Failure to do so    
  could result in serious injury or death. 
•  The ozone generator must be installed in an outdoor location,   

 

  or indoors in a forced air ventilated room, and installed so that the  

 

  orientation is exactly as shown in Figure 1. 
•  Mount the ozone generator so that it is inaccessible to anyone in the    
  pool. Never attempt any servicing while unit is wet. 
•  Plastic ozone supply tubing is supplied with the ozone generator.  

 

  Never replace this tubing with metal tubing. 
•  Warning – Short-term inhalation of high concentrations of ozone and    
  long term inhalation of low concentrations of ozone can cause serious   
  harmful physiological effects. DO NOT inhale ozone gas produced by    
  this device. 
•  For your safety, do not store or use gasoline, chemicals or other  

 

  flammable liquids or vapors near this or any other appliance.

SAVE THESE INSTRUCTIONS!

EC–AG1U, EC–AG2U

Summary of Contents for Big Dipper EC-AG1U

Page 1: ...EC AG1U EC AG2U Installation Operations Manual 4 2353 01 Rev A...

Page 2: ......

Page 3: ...Installation 2A Location 1 2B Wall Mounting 2 2C Electrical 2 2D Plumbing 2 SECTION 3 Operation 3A General 3 3B Initial System Start Up 5 3C System Shut Down 5 SECTION 4 Maintenance Service 4A System...

Page 4: ...nstall in accordance with the installation instructions Follow all applicable electrical codes Electric shock hazard Be sure to turn power OFF and disconnect from power source before any service work...

Page 5: ...B Specifications Flow rate 15 scfh nominal Flow rate and ozone output will vary with installation Power Requirements EC AG1U 120 240V 50 60 Hz 1 0 10 Amp Max EC AG2U 120 240V 50 60 Hz 1 0 05 Amp Max S...

Page 6: ...trical 2C 1 Main Power Connect the Ozone Generator to the pool timing clock so that the Ozone Generator operates simultaneously with the pool pump The circuit must be protected by a ground fault circu...

Page 7: ...Port is accessible d Reconnect the pool s return hose to the outlet of the injector e Attach Hose Barb Fitting to the Ozone Port on the Injector 2D 2 Ozone Gas Line Connect the end of the Ozone Suppl...

Page 8: ...ation Operations Manual Figure 2 Typical Injector Installation Pool without heater EC AG Ozone Generator Ozone Supply Tubing Check Valve Hose Barb Fitting Injector Filter R e t u r n t o P o o l From...

Page 9: ...wn for an extended period disconnect the Ozone Generator power cord and disconnect the Ozone Supply Tubing from the Ozone Generator SECTION 4 Maintenance and Service 4A System Electromechanical Overvi...

Page 10: ...be replaced replacement part number 9 0777 01 immediately WARNING Trace amounts of nitric acid may be present in the check valve or tubing and could be mildly corrosive If condensation is present shut...

Page 11: ...crewdriver or fingers pry the two Cover Tabs outward to release the cover from the base c Lift the cover up Figure 4 d Slide the cover forward and off Figure 3 Cover Screw and Tabs Figure 4 Lifting Co...

Page 12: ...Supply with Mounting Hardware Route Power Supply wires to the left side of the Base Plate i Connect Power Supply connectors to wire harness j Slide cover into position while lifting the base of the co...

Page 13: ...th debris Disconnect the Ozone Supply Tubing from the Injector With the pump running test the end of the Hose Barb Fitting with your thumb and feel for suction Wash your hands immediately afterwards t...

Page 14: ...tability or implied warranty of fitness for particular purpose and such warranties are hereby disclaimed f DEL Ozone shall not be liable under any circumstances for loss of use of such product loss of...

Page 15: ......

Page 16: ...3580 Sueldo Street San Luis Obispo CA 93401 800 676 1335 o3info delozone com www delozone com EPA Estab No 071472 CA 001...

Reviews: