2B. Electrical  

Simply plug the ZO-400 into a properly rated receptacle, installed to 
applicable electrical codes. The receptacle must be protected by a 
GFCI or RCD. 

SECTION 3 Controls

3A. Power

The DEL Ozone Aquaclipse has a power switch on the front panel 
for turning the system on and off. The light next to the switch will 
illuminate when the system is powered on.
3A-1 Indicator lights
1. System Power – The green light in between the timer and the 

switch will light up when the switch is in the on position and the 
system has power.

2. Ozone Modules – To view the Ozone Module lights, open the 

Acess Panel as described in Section 5A. Turn power on briefly to 
view lights. 

DO NOT touch the ZO-400 or the internal components while unit is 
operational

.

3B. Timer

The ZO-400 is equipped with a built-in timer to control the operation 
of the ozone generator. The timer has 96 moveable tabs, each 
representing a 15 minute period of operation. Push the tabs 
INWARD to turn ON the ozonator, and OUTWARD to turn it OFF.

To use the timer, remove the plastic cover and depress enough 
consecutive tabs on the dial for the desired operating time. For 
example, four consecutive tabs need to be pushed in for one 
hour of operation (

Figure 1). Plug in the ZO-400 and turn the 

main power switch on. Rotate the timer clockwise. When the 
first depressed tab reaches the pointer in the center of the timer, 
the ozonator will turn on. The ozonator will turn off again upon 
reaching the first undepressed tab, or when the main power switch 
is turned off.

The timer will continue to run as long as the ZO-400 is plugged 
in, even if the power switch is off. You can set the time of day by 
rotating the dial clockwise until the correct time is lined up at the 
pointer.

SECTION 4 Water Treatment

The ZO-400 Aquaclipse can purify water in atmospheric tanks, 
emergency storage, spas, bathtubs, fountains, and wading pools 
up to 20 feet deep. It is specifically designed to purify drinking water 
from well sources or city water supplies, removing undesirable 
tastes, odors and colors caused by iron, copper, manganese, 
chlorine and organics. The Aquaclipse is especially good at 
removing the sulfur smell from well water.

DO NOT use water from a source that is questionable such as 
stagnant pool water, creeks, ponds, streams, urinary tracts or the 
like.

To treat water, place the dispersion stone into the water container 
as shown in Figure 1 and set the timer to make the unit run for 
the amount of time desired (recommended 24 hr/day operation).  
Running the unit less than 24 hours per day may work for your 
set-up, but running the unit for longer will not hurt the water or the 
system.

When used in conjunction with a particulate filter, ozone will also 
remove excess minerals including iron, manganese, and lead, as 
well as radon and sulfur gases. It is recommended you check your 
filters about 1 month after installation of ozone equipment to gage 
rate of clogging.

POWER 

SWITCH

FUSE 

POWER LIGHT

ACCESS PANEL 
SCREWS

Reviews: