background image

AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems

22

DEL OZONE 

 COMMERCIAL PRODUCT 

LIMITED TWO YEAR WARRANTY 

 

The limited warranty set forth below applies to products manufactured by DEL OZONE – 3580 Sueldo Street, San Luis 
Obispo, California 93401, and sold by DEL OZONE or its authorized dealers. This limited warranty is given only to the first 
retail purchaser of such products and is not transferable to any subsequent owners or purchasers of such products. 
Systems sized 65 grams or greater require factory commissioning and startup to maintain warranty as set forth below. 

DEL OZONE warrants that DEL or DEL authorized dealers will repair or replace, at DEL’s option, any part of such 
products proven to be defective in materials or workmanship within two (2) years of the date of receipt. Parts are covered 
under the two (2) year warranty when and only when the stated maintenance requirements are met.  Contact Tanks and 
degas valves have a ninety (90) day warranty. Compressor(s) must be maintained per operation and maintenance 
manual. Required maintenance includes a compressor rebuild after one (1) year or every 8,760 hours, which ever is 
reached first. Warranty does not include parts for compressor(s) rebuild kit(s), or other consumable items. See owner’s 
manual for complete maintenance details. This Warranty specifically excludes any components not manufactured by DEL 
OZONE that are external to the products covered, such as pumps, air compressors, monitors, tanks, or related 
components. DEL OZONE will assist with warranty claims for such components purchased through DEL OZONE; limited 
to the extent of the manufacturer’s standard warranty. ANY REPAIR OR REPLACEMENT WILL BE WARRANTED ONLY 
FOR THE BALANCE OF THE ORIGINAL TWO (2) YEAR WARRANTY PERIOD 
.

NOTE: USE ONLY DEL AUTHORIZED DEL REPLACEMENT PARTS. USE OF ANY OTHER PART(S) 

WILL VOID 

THIS WARRANTY.

Any replaced parts must be returned to DEL OZONE for warranty evaluation. 

THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF THE FOLLOWING:  

(a)

  

Any labor charges for troubleshooting, removal, or installation of such parts. 

(b)

  

Any repair or replacement of such parts necessitated by faulty installation, improper maintenance, improper 
operation, misuse, abuse, negligence, accident, fire, flood, repair materials, and/or unauthorized accessories. 

(c)

  

Any such products installed without regard to required local codes and accepted trade practices.  

(d)

  

Damage to unit caused by water backflow;  

(e)

  

Any implied warranty of merchantability or implied warranty of fitness for particular purpose, and such 
warranties are hereby disclaimed.  

(f)

  

DEL Ozone shall not be liable under any circumstances for loss of use of such product, loss of profits, direct 
damages, indirect damages, consequential damages, and / or incidental damages.    

This warranty gives you specific legal rights.  You may have other rights which vary from state to state.

Extended Warranties and Service Agreements are available. Contact DEL for additional details.

TO OBTAIN WARRANTY SERVICE:  

DEL OZONE Commercial Department 

PO Box 4509, San Luis Obispo, CA 93403  
Customer Service Number:    

(800) 676-1335  

Fax Number:  

 

 

(805) 541-8459 

mail 

   

[email protected]

PROVIDE:  

 
1. Project, contact name, mailing address and telephone.  
2. Installer/Mechanical Contractor. 
3. Unit Part Number, Serial Number, and date of purchase.  
4. The date of failure. 
5. A description of the failure. 

After this information is provided, DEL Ozone may release a 

RETURN GOODS AUTHORIZATION (RGA) NUMBER. 

After receiving the RGA number 

the part in question must be returned to DEL Ozone, freight prepaid, with the RGA number clearly marked on the outside of the package. All 
preauthorized defective parts must be returned to DEL Ozone within thirty (30) days. Under no circumstances may any product be returned to DEL 
Ozone without prior authorization. Returns without the assigned RGA number on the outside of the package will be refused and shipped back to the 
sender at their expense. Upon receipt of preauthorized returned goods, DEL Ozone will repair or replace, at DEL Ozone’s option, the defective product(s) 
and return them (freight prepaid for products under warranty). Buyer’s acceptance of the product and use thereof constitutes acceptance of these terms 

4-1370-01_Rev.C

Summary of Contents for AGW-4015

Page 1: ...GW 4015 AGW 4025 AGW 4045 Skid Mounted Ozone Sanitation Systems OWNER S MANUAL EPA Estab No 071472 CA 001 DEL OZONE SAN LUIS OBISPO CA 93401 USA 800 676 1335 Fax 805 541 8459 4 0656 Rev F 129380 12938...

Page 2: ...ng Procedures 7 4E1 Clean In Place CIP Operation 8 4E2 Facility Washdown 8 4E3 Direct Contact 8 4E4 General Water Purification 8 SECTION 5 Maintenance Service 5A Preventative Maintenance Schedule 9 5B...

Page 3: ...escribed condi tions as set forth in the owner s manual ANTIMICROBIAL CLAIMS This device has been determined acceptable for use as an ozone generating device providing sanitization and disinfection of...

Page 4: ...t contact on food products and general water sanitation disinfection 1B Specifications Ozone Output g hr 4015 4025 4045 15 25 45 Ozone Flow max scfh 13 18 30 Weight 03 4 2 4 2 4 2 Applied dose ppm Flo...

Page 5: ...AGW 4015 4025 4045 Skid Mounted Ozone Sanitation Systems 2 3A Tank System...

Page 6: ...AGW 4015 4025 4045 Skid Mounted Ozone Sanitation Systems 3 3B Tank Cleaning...

Page 7: ...AGW 4015 4025 4045 Skid Mounted Ozone Sanitation Systems 4 3C Spray System...

Page 8: ...ivates water pump and supplies power to ozone generator b Ozone Power Switch Activates ozone gener ating equipment c Injector Vacuum Gauge Indicates Vacuum of the ozone in the injector system d Vacuum...

Page 9: ...4025 4045 Water Connections AGW 4015 4025 4045 Components Water Pump 1 5 HP Heated Catalytic Ozone Destruct Mixing Tank Degas Valve Venturi Injector Flow Back Pressure Adjustment Valve Vacuum Adjustme...

Page 10: ...xt adjust the vacuum adjustment valve to read 5 in Hg 4 Multiple iterations of adjusting both the flow back pres sure valve the vacuum adjust valve may be required to achieve settings as close as poss...

Page 11: ...E 1b General Tank Sanitation See page 3 drawing 3B Wash debris and rinse the tank with clean water Connect the AGW 4015 4025 4045 to the tank and recirculate the system while spraying with any standar...

Page 12: ...ear panel c Replace the flow meter and tighten the union nut 5D Trouble Shooting also refer to Ozone Gen erator manual Knowledge of electrical applications is required for trouble shooting Contact a c...

Page 13: ...uired b Check for power at input terminals of the HV power supplies c Check ozone power relay for loose connections or faulty operation CAUTION HIGH VOLTAGE 7 000 V VII Symptom No oxygen flow through...

Page 14: ...AGW 4015 4025 4045 Skid Mounted Ozone Sanitation Systems 11...

Page 15: ...AGW 4015 4025 4045 Skid Mounted Ozone Sanitation Systems 12...

Page 16: ...monly hydrogen sulfide 7A 4 Factors Affecting Sanitation The following factors will affect the ability of ozone to effectively act as a sanitizer Type and level of contaminant Physical chemical parame...

Page 17: ...hours 5 days a week OSHA The short term exposure limit is 0 3 ppm averaged over 15 minutes The concen tration of 5 ppm ozone in air is generally accepted as Immediately Dangerous to Life or Health ID...

Page 18: ...hout risk to themselves or others around them All workers must clearly understand their responsibilities with regard to not only specific work procedures but also the need to report all hazards accide...

Page 19: ...ld log ozone monitor output Record ozone output data twice per shift maximum 12 hour shift If system does not have an automatic chart recorder record data every 4 hours regardless of shift changes See...

Page 20: ...AGW 4015 4025 4045 Skid Mounted Ozone Sanitation Systems 17...

Page 21: ...AGW 4015 4025 4045 Skid Mounted Ozone Sanitation Systems 18...

Page 22: ...D O T Shipping Classification NON REGULATED I PHYSICAL DATA Boiling Point 212 F Freezing Point 32 F Specific Gravity 1 0 Solubility in Water COMPLETE Evaporation Rate APPROX 1 Physical Form LIQUID App...

Page 23: ...prevent irritation and drying of the skin V EMERGENCY AND FIRST AID PROCEDURES Eye Contact If exposure to water containing aqueous solution of ozone causes irritation to eyes flush eyes with plenty o...

Page 24: ...he periodic exposure levels established by OSHA for worker safety through the use of DEL s ozone management technology Precautions To Be Taken In Handling Aqueous solutions of ozone in potable water s...

Page 25: ...charges for troubleshooting removal or installation of such parts b Any repair or replacement of such parts necessitated by faulty installation improper maintenance improper operation misuse abuse ne...