DTE-3114 – Networked Quad QAM Modulator 

 

 

USER 

MANUAL

 

 

11 

If the reset button is hold down for more than three seconds, the DTE-3114 will enter failsafe mode, 

see section 2.6. 

2.4 Thermal considerations 

The  DTE-3114  is  designed  to  operate  with  cooling  by  natural  convection,  without  active  cooling 

facilities. However, the following considerations have to be taken into account: 

 

The unit must always be mounted vertically to allow bottom-to-top airflow. 

 

The units must be installed in such a  way that airflow is not obstructed. In no case the vent 

holes should be covered when the DTE-3114 is enabled. 

 

If multiple units are mounted next to each other on a rail, the units should be spaced at least 

0.5cm apart. 

 

The ambient temperature should be lower than 35˚C / 95˚F. If this condition cannot be met, 

forced air cooling should be applied with a vertical-flow fan unit mounted below the units. 

A  thermal  shutdown  mechanism  is  in  place  to  avoid  overheating  of  the  unit.  If  the  internal 

temperature  of  the  DTE-3114  rises  above  85˚C  /  185˚F,  the  RF  output  of  the  device  will  be 

disabled. 

2.5 IP address assignment 

Within  a  network  each  connected  device  needs  to  have  a  unique  IP  address  to  enable  reliable 

communication between the devices. If multiple devices would have the same IP address, conflicts 

may  occur  and  communication  becomes  unreliable.  The  IP  addresses  in  a  network  can  be 

configured by the user with fixed unicast IP addresses or via a DHCP server on the network. 
Upon applying power, the DTE-3114 will try to connect to a DHCP server to obtain an IP address, 

unless a static IP address has been configured. In the latter case, the DTE-3114 will start with the 

configured static IP address. 
If no static IP address has been configured and no DHCP server is running (or if the DHCP server 

cannot  be  reached)  the  DTE-3114  will  automatically  assign  itself  an  address  in  the  range  from 

169.254.1.0 to 169.254.254.255 (Link-local address, RFC 3927) with subnet 255.255.0.0. 
The selected IP address is shown at the bottom of the illuminated LCD display on the DTE-3114. The 

IP address is interchanged with the MAC address every few seconds. 
Note:  The  MAC  address  can  also  be  found  on  the  label  attached  to  the  DTE-3114,  above  the 

network connector. 
A web browser on the same subnet can now be used to connect to the unit, by using the IP address 

as URL, e.g. http://192.168.1.10/. For easy access to a specific DTE-3114, the IP address can be 

added to the list of browser favorites and given a name. 
When you have access to the web pages of the DTE-3114 web interface, you can – if you want to do 

so – assign a static IP address and subnet mask via the Network settings tab. The default gateway 

can be specified, too, but this is not required. 

Summary of Contents for DTE-3114

Page 1: ...DTE 3114 Networked Quad QAM Modulator USER MANUAL Augustus 2013...

Page 2: ...ettings 14 2 7 3 Network Settings 15 2 7 4 Alarm Settings 15 3 Device Configuration and Monitoring 16 3 1 Control interfaces 16 3 2 Manageable items 16 3 2 1 Device 16 3 2 2 Network Settings 17 3 2 3...

Page 3: ...32 5 5 Other Specifications 32 Appendix A DTE MIB 34 Appendix B DTE QAM MIB 47 Copyright 2009 2011 by DekTec Digital Video B V DekTec Digital Video B V reserves the right to change products or specifi...

Page 4: ...d where PoE is not available The DTE 3114 supports SNMP management and has an easy to use web based user interface for configuration purposes as well as retrieving status information and performance s...

Page 5: ...tor The development of silicon tuners and line amplifiers requires simulation of fully loaded spectrum conditions Testing and debugging of Electronic Program Guide EPG and other software for QAM set t...

Page 6: ...Video Broadcasting DVB C DVB standard for modulation appropriate for in cable networks EPG Electronic Program Guide FEC Forward Error Correction IP Internet Protocol LCD Liquid Crystal Display MAC Med...

Page 7: ...rt Stream over IP UDP Unreliable Datagram Protocol UHF Ultra High Frequency band officially ranging from 300MHz to 3GHz but in the context of cable television from 300MHz to 1GHz URL Uniform Resource...

Page 8: ...s to reboot the DTE 3114 or enter failsafe mode if held pressed for more than three seconds 5 RJ 45 Gigabit port The Ethernet port is used to supply TS over IP input Web and SNMP management and option...

Page 9: ...mber of channels that have been enabled If no channels are active Idle is displayed 3 Mode QAM mode and modulation standard 4 RF level Total output power level in dBm 5 Frequency Carrier frequency of...

Page 10: ...thernet PoE Alternatively when the switch supports Ethernet without PoE a 24V 400mA power adapter can be applied using the auxiliary 24V DC power jack If both PoE and auxiliary power are supplied the...

Page 11: ...e same IP address conflicts may occur and communication becomes unreliable The IP addresses in a network can be configured by the user with fixed unicast IP addresses or via a DHCP server on the netwo...

Page 12: ...d on the network segment connected to the network card with IP address 192 168 200 3 and has assigned itself link local IP address 169 254 225 123 The route print command may give the following result...

Page 13: ...ble Example 2 Same situation as example 1 but now the route print gives the following result C route print Interface List 0x1 MS TCP Loopback interface 0x2 00 14 f4 00 00 2b DekTec DTA 160 Gigabit Eth...

Page 14: ...button is kept pressed for at least 3 seconds In the latter two cases the DTE 3114 will obtain an IP address through DHCP even if a static IP address was configured In failsafe mode just 3 tabs are e...

Page 15: ...Display ID blank SNMP agent disabled SNMP read community public SNMP write community private SNMP traps disabled SNMP trap destination 0 0 0 0 SNMP trap community public SNMP trap Port 162 2 7 4 Alarm...

Page 16: ...e Variable Description Web SNMP Device type Device type number 3114 for DTE 3114 RO RO Serial number Unique serial number for the device It always starts with 3114 followed by 6 digits RO RO Hardware...

Page 17: ...ze the value of the MIB objects with the current run time settings see section 3 4 2 NA WO 3 2 2 Network Settings Variable Description Web SNMP MAC address The MAC address of the device RO RO DHCP ena...

Page 18: ...lost IP packets Error recovery is only possible if the transmitter uses the RTP protocol with FEC packets R W R W IP to output delay The desired delay in ms between the reception of an IP packet and...

Page 19: ...correct The settings should be modified before they can be applied No input error The channel is enabled but no valid IP stream is present RO RO Protocol IP protocol used by the incoming IP stream UDP...

Page 20: ...every second RO RO Clear counters Clears the Lost before FEC Lost after FEC and Lock error counters in the web interface WO NA 3 2 6 SNMP alarms Variable Description Web SNMP Temp alarm enable Enable...

Page 21: ...and information about the incoming TSoIP streams Per channel three counters maintaining statistics about the IP stream are displayed Each channel has a clear button for clearing the counters SMPTE Set...

Page 22: ...will appear Only when there is no error anymore the settings can be applied In general the settings error is linked to a setting or to a combination of settings on the same web page However in except...

Page 23: ...ngs An NMS can force a certain parameter set by writing the required values to all MIB objects that represent a writeable parameter Doing this will not interrupt the operation of channels which had th...

Page 24: ...d 3 Symbol rate is out of range 4 Interleaver I is out of range 5 Interleaver J is out of range 6 Frequency is out of range 7 Overall spectrum cannot be wider than 32 MHz The difference between the hi...

Page 25: ...page of the web interface First the required DTE 3114 firmware file must be obtained e g from the DekTec website An upgrade file normally has the extension dte Put this file somewhere on a local disk...

Page 26: ...e to know the maximum amount of jitter so that it can compensate 4 2 Managing bitrates The bitrate of an incoming IP streams may not exceed the nominal bitrate of the QAM modulator channel which depen...

Page 27: ...bol rate MBd Bandwidth MHz Bitrate Mbps 64 QAM 4 48 5 29 23 893333 5 056941 5 97 26 970352 256 QAM 4 48 5 02 32 435545 5 360537 6 00 38 810701 Not a typical QAM B bitrate This is the minimum symbol ra...

Page 28: ...ft and or route changes in the network These will manifest itself as jitter in the arrival time of the IP packets so called IP jitter A non ideal transmitter adds to the IP jitter The DTE 3114 can tol...

Page 29: ...29 RxIpJitterErrorCounter not visible in the web page and will result in lock errors increment of nwRxLockErrorCounter and visible on the IP status webpage After a lock error the channel will restart...

Page 30: ...and Ethernet II IP version IPv4 IP address assignment DHCP or static Multicast support IGMP v2 Network management SNMP v2c MIBs MIB II DTE MIB DTE QAMMOD MIB Discovery WS Discovery 5 2 Transport Stre...

Page 31: ...n loss 14 5 dB 32 1006MHz Output level 3 32 9 dBm Step size 0 5 dB Accuracy 1 dB Output level differential 4 3 3 dB Spectral purity 60 dB 9dBm output Monitor RF Port Connector type F Female Impedance...

Page 32: ...32 64 128 256 QAM Symbol Rate Range 6 4 48 6 9 7 0 MBd Resolution 1 Bd MER equalised 43 dB Spectrum flatness 1 channel 0 2 dB Shoulder attenuation 48 dB 9dBm output 6 This symbol rate range is support...

Page 33: ...AL 33 Min Typ Max Mechanical Mounting DIN rail TS35 TS32 Dimensions W x H x D 34 x 133 x 133 34 x 133 x 155 mm no clicker mm with clicker Weight 324 340 g no clicker g with clicker 7 Pending formal va...

Page 34: ...ned to be independent of the number of supported input and outputs enterprises 27070 3 1 DekTec s private enterprise number dektec OBJECT IDENTIFIER enterprises 27070 dte OBJECT IDENTIFIER dektec 3 Fo...

Page 35: ...reRevision OBJECT TYPE SYNTAX Integer32 MAX ACCESS read only STATUS current DESCRIPTION Hardware revision number device 3 devFirmwareVersion OBJECT TYPE SYNTAX Integer32 MAX ACCESS read only STATUS cu...

Page 36: ...2 MAX ACCESS read only STATUS current DESCRIPTION Reflects the status of the device 0 normal operation 1 hardware error 2 channel error 3 temperature error device 11 Group system snmpTraps snmpTrapEna...

Page 37: ...SS not accessible STATUS current DESCRIPTION A network receive channel entry containing objects with control and status data INDEX nwRxIndex nwRxTable 1 NwRxEntry SEQUENCE nwRxIndex Integer32 nwRxSink...

Page 38: ...read write STATUS current DESCRIPTION Enable or disable this channel 0 disable the channel 1 enable the channel DEFVAL disable nwRxEntry 4 nwRxAddressingMethod OBJECT TYPE SYNTAX INTEGER unicast 0 any...

Page 39: ...ut 4 MAX ACCESS read only STATUS current DESCRIPTION Current operational status of the channel 0 channel is enabled and there are no problems 1 channel has been disabled 2 there is a problem with the...

Page 40: ...an IP packet in a 2D FEC block nwRxEntry 19 nwRxTsPacketSize OBJECT TYPE SYNTAX INTEGER bytes188 0 bytes204 1 MAX ACCESS read only STATUS current DESCRIPTION Size of the MPEG 2 packets in the receive...

Page 41: ...ent DESCRIPTION Counter that keeps the number of channel restarts A channel is restarted only under adverse circumstances like large jitter of IP packets in combination with packet loss A channel rest...

Page 42: ...ger32 nwTxTimeToLive Integer32 nwTxProtocol INTEGER nwTxNumberOfTpPerIp Integer32 nwTxFecEnable INTEGER nwTxFecNumberOfRows Integer32 nwTxFecNumberOfColumns Integer32 nwTxIpAddressStatus INTEGER nwTxF...

Page 43: ...nt DESCRIPTION Time to live The generated IP packets will use the TTL specified by this value nwTxEntry 7 nwTxProtocol OBJECT TYPE SYNTAX INTEGER udp 0 rtp 1 MAX ACCESS read write STATUS current DESCR...

Page 44: ...ets in the transmitted transport stream nwTxEntry 15 nwTxSettingsStatus OBJECT TYPE SYNTAX Integer32 MAX ACCESS read only STATUS current DESCRIPTION Channel status The status is either ok or an error...

Page 45: ...wRxIpPort nwRxMulticastAddress nwRxSourceSpecificMulti nwRxFecEnable nwRxIpToOutputDelay nwRxOperationalStatus nwRxProtocol nwRxNumberOfTpPerIp nwRxFecNumberOfRows nwRxFecNumberOfColumns nwRxIpLostBef...

Page 46: ...ce STATUS current DESCRIPTION A collection of objects providing network transmit information groups 5 devAlarmTrapGroup NOTIFICATION GROUP NOTIFICATIONS trTemperatureError STATUS current DESCRIPTION A...

Page 47: ...The DTE QAMMOD MIB main groups alarms OBJECT IDENTIFIER qammod 1 outputs OBJECT IDENTIFIER qammod 2 traps OBJECT IDENTIFIER qammod 3 groups OBJECT IDENTIFIER qammod 4 Group alarms almRfAlarmValue OBJ...

Page 48: ...2 outInterleaverJ Integer32 outRfLevel Integer32 outSettingsStatus Integer32 outIndex OBJECT TYPE SYNTAX Integer32 1 65535 MAX ACCESS read only STATUS current DESCRIPTION A unique index value for each...

Page 49: ...ntry 8 outInterleaverI OBJECT TYPE SYNTAX Integer32 MAX ACCESS read write STATUS current DESCRIPTION If the modulation standard is j83 annex b this settings specifies interleaver parameter I outEntry...

Page 50: ...PTE settings are not consistent outEntry 12 DTE Alarm Traps trRfLevelError NOTIFICATION TYPE OBJECTS almRfAlarmValue STATUS current DESCRIPTION RF output level error The difference between the device...

Reviews: