background image

23(5$7,21

Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor 
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the “off” 
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles 
occur on any connection there may be a leak. 

If you smell gas or a leak is discovered turn the 

gas valve off, disconnect propane gas tank and do not use the appliance until the leak is 

repaired.

Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion 
you must replace the hose (if applicable). 

Pumice stones/lava rocks/LavaGlass

 could pop up and 

strike somebody’s face during the process of lighting this unit; stand away from the unit for the first 
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.

Wait 50 minutes after extinguishing flame prior to placing a lid (if applicable) or protective cover on

heating item.

1.Make sure the control knob (M) is in the "OFF" position.

2.Open the door (C) and slowly open the valve on the propane gas tank by turning the knob

counterclockwise.

3.Close the door (C) on the body.

4.Push the ignition control knob in fully and rotate about 1/4 turn counterclockwise until a

click is heard,

it may take several attemps to light the burner.

2QFHOLWNHHSKROGLQJGRZQ

WKHFRQWURONQREIRUVHFRQGV

5.If ignition doesn't occur within a few seconds, release the control knob (M) and rotate

to the "OFF" position.

Wait for 5 minutes for gas to clear and then repeat the above

lighting instructions.

6.To adjust the flame, turn the control knob (M) either clockwise or counterclockwise

depending on whether you want to lower or raise the flame.

7R/LJKW

Reviews: