Page 1

Installation & Use Manual

Soft Sides

®

 Fountains with FLEXI-GUARD

®

To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE 

INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR 

INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER 

APPLICABLE CODES. After installation, leave these instructions inside the fountain 

for future reference.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO

WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY

OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK

INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN

INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING

THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER

SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING

PLUMBING SYSTEM.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

FIG. 2

FIG. 1

ECDFPW314C

Installer

NOTE: WATER FLOW

            DIRECTION 

BUILDING WATER

            INLET

    SERVICE STOP

(NOT FURNISHED)

1/4" O.D. TUBE

WATER INLET

TO COOLER

3/8" O.D. UNPLATED COP-

PER TUBE CONNECT

COLD WATER SUPPLY

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Summary of Contents for Soft Sides ECDFPW314C

Page 1: ...TAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON FIG 2 FIG 1 ECDFPW314C Installer NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP...

Page 2: ...LY 1 4 6mm DIA HOLES FOR MOUNTING PLATE TO WALL 3 8 10mm DIA HOLES FOR MOUNTING PLATE TO WALL 10 10 3 8 264mm 8 203mm 8 203mm D 5 1 4 133mm 5 1 4 133mm 8 203mm 8 203mm FINISHED FLOOR FIG 3 LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM WALL SHUT OFF BY OTHERS B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN C 1 1 4 DRAIN FURNISHED D O...

Page 3: ...ak check is completed DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O RINGS MAY RESULT 8 These products are designed to operate on 20 105 PSI supply line pressure If inlet pressure is above 105 PSI a pressure regulator must be installed in the supply line Any damage caused by reason of connecting these products to supply line pressure lower than 20 PSI or higher than 105 PSI is n...

Page 4: ...75672C 112627543890 55996C 28790C 55000665 28290C 40045C 28824C 28286C 56092C 97446C 56369C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 NS DESCRIPTION FIG 8 NOTE WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL TIGHTEN LOCKNUT ONLY TO HOLD PARTS SNUG IN POSITION DO NOT OVER TIGHTEN FIG 6 17 2 2 2 3 4 18 14 SEE FIG 6 OR 7 16 SEE FIG 5 15 1 9 10 13 FIG 5 FIG 7 20 19 20 8 5 7 12 11 29 29 9 ...

Reviews: