Dekko FPI-DECK20SQ Manual Download Page 5

 

 

 
 

       1915 Setterington Drive 

Kingsville • Ontario 

Canada • N9Y 2E5

 

 

 

 
Section 4. 

Natural Gas and Propane Connections   

 

 

 

 

 

 

 

Our fire features arrive pre-assembled with the burner and key valve intact.  
 
Please  refer  to  the 

burner  manufacturer’s  instruction  manual

  included  in  your  delivery  for 

instructions regarding installation, clearances and operation.  
 
Each of our fire pits are built with 

air-flow openings

 that comply with ventilation requirements.  

 
 

PLEASE NOTE:

 

VENTILATION AREAS

 

MUST REMAIN

 

OPEN AND UNBLOCKED 

 
 

Ventilation openings may be used to accommodate running a gas line. 

 

Note regarding ELEMENT and SERENADE fire features:

 

If the gas line needs to be placed in a different location, a hole can be drilled in the fire pit using 
a 1” paddle bit. After removing the burner, drill the hole from the 

inside

 of the fire pit. 

 
 

Section 5. 

Completing the Installation Process 

 

 

 

 

 

 

 

 

After the gas connections are complete in accordance with the 

burner manufacturer’s instruction 

manual

, insert burner tray into position on your fire pit.  

 

AVOID 

covering the burner holes as much as possible when arranging Lava Rock or Decorative 

Stone on your fire feature: 
 

 

Lava Rock

 

Ø

 

Use the provided lava rock and place directly on top of the burner’s surface; the 
lava  rock  aggregate  must  be  placed  on  the  burner 

before 

the  decorative  stone.  

 

 

Decorative Stone

 

Ø

 

Once  the  lava  rock  is  in  place,  distribute  beach  stone  or  crushed  glass  over  the 
entire surface area and cover all lava rock.  

 

 
 

Summary of Contents for FPI-DECK20SQ

Page 1: ...ations of Your Fire Feature 7 6 2 Match Lit Burner Start Up Procedure 7 6 3 Match Lit Burner Shut Off Procedures 7 6 4 Safe Use of Electronic Ignition Burners 8 6 5 Emergency Shut Off Procedures 8 6 6...

Page 2: ...d gas technician Be performed by a licensed electrician for E I fire features only Comply with your local building code PLEASE BE ADVISED Improper installation alterations or maintenance may cause inj...

Page 3: ...ekko Fire Feature Corresponding Burner Burner Manual Chrome Key N A for Electronic Ignition Units Black Lava Rock Choice of Decorative Stone Glass Additional Item s Propane Units Only 12 Extension Hos...

Page 4: ...can view our instructional video that is listed on our website under the FAQ section www dekko ca Section 3 Installing Your Fire Feature on a Combustible Surface WITH THE USE OF AN INSULATION KIT Dek...

Page 5: ...he gas line needs to be placed in a different location a hole can be drilled in the fire pit using a 1 paddle bit After removing the burner drill the hole from the inside of the fire pit Section 5 Com...

Page 6: ...r popping may occur when heated When using your fire pit for the first time it is recommended to burn the fire pit for at least 1 2 hours while keeping a safe distance in the rare event that breakage...

Page 7: ...re NOT to be used as a cooking appliance 6 2 Match Lit Burner Start Up Procedures To activate your fire feature insert the chrome key into the key valve and slowly turn it counter clockwise as indicat...

Page 8: ...isable hydro through a wall timer For more information pertaining to electronic ignition safety and usage please refer to the burner manufacturer s instruction manual included in your delivery 6 5 Eme...

Page 9: ...water properly and drainage ventilation openings are not obstructed by debris Cover your fire pit when it is not in use for extended periods of time 7 2 Removing Stains Concrete can be cleaned with a...

Page 10: ...nnually to promote the longevity and safe usage of your product Ensure gas to the fire pit is shut off and the fire feature is completely cooled before servicing or cleaning If flames exhibit abnormal...

Page 11: ...nless Steel Pan Fire Ring Limited Lifetime Limited Lifetime LP Pressure Regulator 3 Years 1 Year 12 LP Extension Hose 2 Years 2 Years ELECTRONIC IGNITION FIRE PIT COMPONENTS RESIDENTIAL APPLICATION CO...

Page 12: ...ur fire pit flame level may happen for various reasons depending on the model of your fire pit Lower flame levels may be the result of improper gas pressure or inadequate gas supply line If the proced...

Page 13: ...soot can be removed by washing stones with soap and water Cracking Popping Stones The lava rock and beach stone supplied with all DEKKO fire pits originate from a volcanic region are considered heat r...

Page 14: ...s fire pit below the decksurface Do not block any enclosure ventilationholes Concrete pad must be a minimum of 1 thick height Alternative thicknesses must be approved by HPC Always wear gloves and pro...

Page 15: ...ut along the lines from Step 4 and 6 Discard scrap pieces 6 With the Aluminum side UP insert the Basalt material over the supply line Push the Basalt material all the way down until it rests on top of...

Page 16: ......

Page 17: ......

Reviews: