Basalt Material (Square)
Fire Pit Enclosure Construction:
1)
Refer to “Deck Insulation Kit – Install”
for enclosure venting requirements.
2)
Drill hole in concrete pad slightly larger than the supply
line and install concrete pad over supply line. See Fig.1.
For Fire Pit Bowls:
1)
Using the measurement of the inside of the firepit
from Step 1, add 1” to each dimension and draw on
the basalt material. See Fig. 2.
2)
Measure the location of the supply line in relation to
the inside perimeter of the fire pit.
3)
Transfer this supply line measurement to the Basalt
material by drawing an “X”. See Fig. 2.
4)
The “X” should be no larger than the diameter of the
supply line for a tight fit.
5)
Using scissors or cutting tool, cut along the lines from
Step 4 and 6. Discard scrap pieces.
6)
With the Aluminum side UP, insert the Basalt
material over the supply line. Push the Basalt
material all the way down until it rests on top of the
concrete pad. See Fig. 3.
Note:
Check to ensure there are no gaps around the supply line.
Fire Bowl Installation:
Please refer to “Dekko Deck Insulation Kit – Install”
drawing on the last 2 pages.
Square fire pit
Round:
Inside diameter
of fire pit + 1”
Fig. 1
Supply
Line
Concrete pad with
drilled Hole
Inside Fire Pit
Perimeter
Fig. 2
General Information:
For additional information on installing fire bowls and construction for combustible deck systems, see
“Dekko Deck Insulation Kit – Install” drawing 1 of 2.
For concrete fire bowls, refer to “Dekko Deck Insulation Kit – Install” drawing 2 of 2.
Always ensure the decking material will allow for the additional weight of the fire pit.
Fig. 3
Basalt-
Aluminum
Side UP