2. Technical Data
Dimensions:
mm (inch) W x H x D
278 x 238 x 86 (10.9 x 9.4 x 3.4)
Weight:
kg (lbs)
2.5 (5.5)
Housing Material:
ALUMINIUM, VA, ABS/PMMA
Protection Class:
IP 65
Operating Temperature:
°C (°F)
-20 ... 50 (-4 ... 122)
Relative Humidity:
5 %...95%, non-condensing
Power Requirement:
12...24 VDC / max. 10 W
Frequencies:
865 – 868 MHz (EU) or
902 – 928 MHz (US) or
953 – 956 MHz (JP)
Transmit Power:
max. 1.6 W E.R.P. (ETSI EN 302 208) or
(FCC Part 15), configurable
Antenna(s) with
beam width:
≤70°
polarization:
circular (LHCP or RHCP),
adjustable or linearly (vertical or horizontal), adjustable
Transponder Protocols:
ISO18000-6 C (EPC Class1 Gen2)
Anti-Collision:
Identification of several transponders in the antenna field
Reading Distance:
m (ft.)
up to 4 (13.1), depending on transponder, antenna
configuration and environmental conditions
Writing Distance:
up to 50% of reading distance, depending on transponder,
antenna configuration and environmental conditions
Interface:
RS485
Conformity:
Human Exposure
EN 50364
EMC
EN 301 489
Air Interface
EN 302 208 (DRM)
V14/05/09
896108_wi_en_li_udl-250_pro_v130214_io_sk_fh_bf.odt
5
Wiring and Installation UDL 250