9.1.2 Basic Setup
Figure 9.1.2.1: WebConfig – Basic Setup
enable RS485 termination
If this check box is activated, the internal RS485 termination of the device is on.
read mode
This parameter defines, if the reader expects only one tag in the antenna field or if there
may be more tags within the antenna field. In case there are more tags, the reader has to
execute an anticollision algorithm. It is also possible to configure the reader to “single
shot” mode in which the read signalling for the same transponder is only done once or
after a timeout defined by parameter “tag timeout”.
anticollision:
Operating mode in case there is more than one tag in the field
single shot:
Operating mode for reading tag data in case there is only one tag
in the field. The tag data will be transmitted again after the time
period specified in “tag timeout”.
tag timeout / ms (for read mode “single shot” only)
Break between transmission of transponder data within single shot mode. After this timeout
has expired reading the same tag will be signalled again.
RF power / dBm
This value defines the radiated power for the antenna in dBm. The maximum output power
of the antenna is 32 dBm (1.6 W E.R.P.; see also Table 9.1.3 “Antenna Power Table“)