background image

DPS-1 Installation and operation instructions 4189360002 Rev. C 

Mechanical mounting 

www.deifwindpower.com 

Page 9 of 14 

 

4.1

 

DIN rail mounting 

For DIN rail mounting just clips the DPS-1 onto the DIN rail (first top, then bottom). 

4.2

 

Chassis mounting: 

 

Use eye, hand and hearing protection 

Use protection for eyes, hand and hearing, if the mounting holes for bolts need 
to be made during installation. 

 

Drill six 

4 mm holes according to 

Figure 2

 on pag

9

 and the cabinet drawings for mounting 

the DPS-1. Use 4 pcs. 4 mm screws and nuts to mount the DPS-1. Torque according to bolt 
specification. 

107 m

m

141 mm

 

Figure 2

 

DPS-1 2405 drilling drawing 

 

 

 

 

Info 

The vibration, shock and bump specifications apply for chassis mounting only 

Summary of Contents for DPS-1

Page 1: ...AND OPERATION INSTRUCTIONS Power supply DPS 1 Document no 4189360002 Rev C Date 2017 06 27 Language EN GB DEIF A S Frisenborgvej 33 DK 7800 Skive Tel 45 9614 9614 Fax 9614 9615 Info deif com www deifw...

Page 2: ...this document is the original language and always contains the most recent and up to date information about the product Translations might not be updated at the same time as the English version DEIF...

Page 3: ...3 1 Package content 6 3 1 1 Standard package content 6 3 2 Required tools and accessories 6 3 3 Handling 6 4 Mechanical mounting 8 4 1 DIN rail mounting 9 4 2 Chassis mounting 9 5 Electrical connectio...

Page 4: ...N A A Not used 1 2 Conventions The following conventions are used in this document Used in document Description A yellow symbol that illustrates hazard type this symbol is an example for general haza...

Page 5: ...be grounded if possible in order to protect the units and the persons working with them During normal operation the persons working with the units must have no contact to dangerous voltages within th...

Page 6: ...nect wires Wire insulation stripping tool N A Strip wires insulation Press tool for ferrules N A Press ferrules on wires Ferrules recommended N A Terminate wires to connectors recommended different si...

Page 7: ...Package content tools and handling www deifwindpower com Page 7 of 14 Sufficient care must be taken to protect the terminal against electrostatic discharges during the installation Once the unit is in...

Page 8: ...02 Rev C Mechanical mounting www deifwindpower com Page 8 of 14 4 Mechanical mounting 150 154 120 70 141 107 116 78 8 Figure 1 DPS 1 2405 mechanical drawing The DPS 1 can be mounted on a 35 mm DIN rai...

Page 9: ...d and hearing protection Use protection for eyes hand and hearing if the mounting holes for bolts need to be made during installation Drill six 4 mm holes according to Figure 2 on page 9 and the cabin...

Page 10: ...of 14 5 Electrical connections 5 1 Connection diagram The following figure shows the connections to the DPS 1 Protective Earth input 1 2 3 DC OK DC OK 24V DC Out 5 4 6 7 8 DPS 1 Figure 3 Connection di...

Page 11: ...ires to connectors Table 2 Technical data for all connectors D ZFKDS 2 5 Conductor cross section flexible without ferrule 0 2 to 2 5 mm2 Conductor cross section flexible with ferrule without plastic s...

Page 12: ...s the double current or double length will also double the voltage drop Example 1 5 mm2 5 m 5A V 0 6 V Setting 24 0 0 6 24 6 V 6 2 Visual and electrical monitoring DPS 1 has two monitoring types Elect...

Page 13: ...nt Waste electrical and electronic equipment WEEE must therefore be disposed of properly In Europe the disposal of WEEE is governed by the WEEE directive issued by the European Parliament DEIF complie...

Page 14: ...urrent C degrees Celsius Temperature F Fahrenheit 32 5 9 g gram Weight oz ounce 1 g 0 03527 oz Hz hertz Frequency cycles per second kg kilogram Weight lb pound 1 kg 2 205 lb m metre length ft foot or...