IEC 60417-6182:

Installation, 

electrotechnical expertise

IEC 60417-6183:

Installation, 

mechanical expertise

 

Only qualified and trained lightning protection specialists are allowed to install the tripod.

  The tripod may only be installed under the conditions shown and referred to in these installation 

instructions.

  Prior to installation, the tripod must be examined for good order and condition. If damage or any 

other defect is found, it must not be installed.

  For safety reasons, installation work must be stopped as soon as a thunderstorm approaches/ is 

noticed.

  The installation of components from other manufacturers or of other types is impermissible and will 

void warranty.

  When installing the tripod on sensitive surfaces such as roof sheetings, it must be ensured that these 

surfaces are not damaged.

  It is recommended to wear sturdy shoes (e.g. safety shoes) during installation work.

  When installing the tripod in conjunction with a supporting tube and HVI Conductors, the installation 

notes of the relevant installation instructions must be observed:

 

 

HVI

®

power,  

publication No. 1829

   HVI

®

power long, 

publication No. 1829

 

 

Installing HVI

®

long Conductors inside/outside the supporting tube, 

  

publication No. 1841

   These installation instructions can be downloaded at

 www.dehn-international.com

.    

 

For application-specific questions, please contact the relevant sales team or the DEHN representative 

in your country.

Observe installation instructions!

  2. Safety instructions

Summary of Contents for 105 351

Page 1: ... Copyright 2017 DEHN SÖHNE Blitzschutz Erdung Montageanleitung Dreibeinstativ Art Nr 105 351 für HVI Leitung im Stützrohr DE www dehn de Publication No 1890 Update 09 17 Mat No 3001973 ...

Page 2: ...tiv 5 3 2 Betonsockel 5 3 3 Montage Stützrohr mit Fangspitze 8 3 4 Anschluss an den Potentialausgleich 8 4 Anpassung bei einem Dachneigungswinkel bis 10 10 4 1 Adaptereinstellung 10 5 Montage unter Berücksichtigung der Windzone Windgeschwindigkeit 12 Inhaltsverzeichnis ...

Page 3: ...Einsatz des Stützrohres ist das Schutzwinkelverfahren anzuwenden Der Schutzwinkel α ist abhänig von der Schutzklasse Gefährdungspegel und der Höhe des Stützrohres mit Fang stange über der Bezugsebene Die Werte können aus der DIN EN 62305 3 VDE 0185 305 3 Tabelle 3 entnommen werden siehe auch Fig 1 und Tabelle 1 Gleichermaßen kann bei der Positionierung des Stützrohres mit Fangstange das Blitzkugel...

Page 4: ...pfremder Komponenten sind unzulässig und führen zum Erlö schen des Gewährleistungsanspruches Bei der Montage der Stative auf empfindlichen Untergründen wie z B Foliendachbahnen usw ist darauf zu achten dass keinerlei Beschädigungen entstehen Bei den Montagearbeiten empfiehlt es sich festes Schuhwerk z B Sicherheitsschuhe zu tragen Bei der Montage der Stative in Kombination mit Stützrohr und HVI Leit...

Page 5: ...Nr 1 und Nr 2 fest verschraubt werden Dabei ist einAnzugsdrehmoment von 25 Nm anzusetzen siehe Fig 2 äußere Streben aufklappen aufklappen Feststellschraube Nr 1 Flachkopf Schraube M10 mit Scheibe und Sechskantmutter M10 Feststellschraube Nr 2 Flachkopf Schraube M10 mit Scheibe und Sechskantmutter M10 Fig 2 Dreibeinstativ 3 2 Betonsockel In Abhängigkeit der jeweiligen Gesamtlänge der Stützrohre und...

Page 6: ...el oberhalb der Strebe 1 x HVI long Leitung 4 Sockel R 620 mm Ø 20 23 außen verlegt min 2 Sockel unterhalb der Strebe 2 Sockel oberhalb der Strebe 2 x HVI long Leitung 4 Sockel R 620 mm Ø 20 23 außen verlegt min 2 Sockel unterhalb der Strebe 2 Sockel oberhalb der Strebe 3 x HVI long Leitung 4 Sockel R 620 mm Ø 20 23 außen verlegt min 2 Sockel unterhalb der Strebe 2 Sockel oberhalb der Strebe 3 x H...

Page 7: ... bzw außerhalb der Stützrohre sind den entsprechenden Montageanleitungen zu entnehmen HVI power Publication No 1829 HVI power long Publication No 1829 HVI long Leitung Verlegung im am Stützrohr Publication No 1841 Betonsockel bohrung Betonaus sparung Stab Strebenverankerung Arretierungsschraube M10 x 30 25 Nm Strebe Befestigungskeil Durchsteckschutz ausschlagen Schnittbild Betonsockel Betonsockel ...

Page 8: ...retierungsschrauben M10 Anzugsdrehmoment 25 Nm festge schraubt Dabei müssen die vier Sechskantmuttern M 10 gegen den Adapter gekontert werden siehe Fig 5 Seite 9 3 4 Anschluss an den Potentialausgleich Bei der Verwendung des Dreibeinstativs in Verbindung mit einer HVI long Leitung oder HVI power Leitung erfolgt der Anschluss an den Potentialausgleich über den Doppelüberleger V2A Dabei ist ein Anzu...

Page 9: ...erungsschraube n 2 x M8 15 Nm Stützrohr Ø 50 mm Länge 3200 mm Rund Arretierungsschraube n 4 x M10 25 Nm Befestigungskeil Dreibeinstativ Betonaussparung Sechskantmutter n M10 Adapter Aufnahme Betonsockel Fig 5 Strebengestell Betonsckel Fangstange Strebe ...

Page 10: ...tung des Neigungswinkels wird das Stützrohr mit Fangspitze in denAdapter eingeführt und mittels den vier Arretierungsschrauben M 10 festgeschraubt Zusätzlich müssen die vier Sechskantmuttern gegen denAdapter gekontert werden Die vorgegebenen Anzugsdrehmomente sind dabei zu beachten siehe hierzu Fig 6 Seite 10 und Fig 7 Seite 11 Fig 6 Adaptereinstellung Anzugsdrehmoment Arretierungsschraube M 10 25...

Page 11: ...angstange Adapter befindliche Strebe immer parallel zur Dachaussenkante verläuft siehe Fig 7 Seite 11 Dreibeinstativ Stützrohr Ø 50 mm Länge 3200 mm Rund Arretierungsschraube n 2 x M8 15 Nm Fangsspitze Niro Ø10 mm Länge 1000 mm Rund Fig 7 Dreibeinstativ bei einer Dachneigung von max 10 max 10 Parallelverlauf ...

Page 12: ...ehe Fig 8 Beim Errichten von Fangeinrichtungen außerhalb des Bundesgebietes sind die entsprechenden landesspezifischen Angaben zu den Windzonen Windgeschwindigkeit zu berücksichtigen In die Berechnung der tatsächlichen zu erwartenden Windlastbeanspruchung geht neben der zonen abhängigen Windlast auch die Gebäudehöhe und die örtlichen Gegebenheiten Gebäude einzeln stehend im offenen Gelände oder ein...

Page 13: ...7 NOTIZEN ...

Page 14: ...Überspannungsschutz DEHN SÖHNE Hans Dehn Str 1 Tel 49 9181 906 0 Blitzschutz Erdung GmbH Co KG Postfach 1640 www dehn de Arbeitsschutz 92306 Neumarkt DEHN schützt Germany ...

Page 15: ...N SÖHNE Lightning protection Earthing Installation instructions Tripod Part No 105 351 for HVI Conductors installed inside the supporting tube GB www dehn international com Publication No 1890 Update 09 17 Mat No 3001973 ...

Page 16: ... Concrete base 5 3 3 Installation of the supporting tube with air termination tip 8 3 4 Connection to the equipotential bonding system 8 4 Adaptation to roof pitches up to 10 10 4 1 Adjustment of the adapter 10 5 Installation with regard to the wind zone wind speed 12 Contents ...

Page 17: ...ing a supporting tube the protective angle method must be used The protective angle α depends on the class of LPS lightning protection level and the height of the supporting tube above the reference plane The relevant values can be found in Table 3 of IEC 62305 3 see also Fig 1 and Table 1 As an alternative the rolling sphere method can be used to position the sup porting tube Table 1 Calculation ...

Page 18: ... types is impermissible and will void warranty When installing the tripod on sensitive surfaces such as roof sheetings it must be ensured that these surfaces are not damaged It is recommended to wear sturdy shoes e g safety shoes during installation work When installing the tripod in conjunction with a supporting tube and HVI Conductors the installation notes of the relevant installation instructi...

Page 19: ...f locking screws No 1 and 2 using a tightening torque of 25 Nm see Fig 2 outer braces unfold unfold Locking screw No 1 M10 slotted pan head screw with washer and M10 hexagon nut Locking screw No 2 M10 slotted pan head screw with washer and M10 hexagon nut Fig 2 Tripod 3 2 Concrete base Depending on the relevant total length of the supporting tubes and the possible wind loads the relevant number of...

Page 20: ...th the brace the supporting tube 2 bases above the brace 2 x HVI long Conductor 4 bases r 620 mm Ø 20 23 installed outside at least 2 Sockel bases underneath the brace the supporting tube 2 bases above the brace 3 x HVI long Conductor 4 bases r 620 mm Ø 20 23 installed outside at least 2 Sockel bases underneath the brace the supporting tube 2 bases above the brace 3 x HVI long Conductor 4 bases r ...

Page 21: ...de the supporting tube can be found in the relevant installation instructions HVI power publication No 1829 HVI power long publication No 1829 HVI long Conductors inside outside the supporting tube publication No 1841 hole in the concrete base concrete recess rod brace anchor locking screw M10 x 30 25 Nm brace fixing wedge remove concrete fin sectional view of the concrete base concrete base Part No...

Page 22: ...me and tighten it by means of the four M10 locking screws tightening torque of 25 Nm In this process the four M10 hexagon nuts must be tightened against the adapter see Fig 5 on page 8 3 4 Connection to the equipotential bonding system When using the tripod in conjunction with a HVI long or HVI power Conductor the connection to the equipotential bonding system is established via a double cleat V2A...

Page 23: ... round 2x M8 locking screw s 15 Nm supporting tube Ø 50 mm 3200 mm long round 4x M10 locking screw s 25 Nm fixing wedge tripod concrete recess M10 hexagon nut s M10 adapter concrete base Fig 5 Brace frame concrete base air termination rod brace ...

Page 24: ... angle the supporting tube with air termination tip is inserted into the adapter and tightened by means of the four M10 locking screws In this process the four hexagon nuts must be tightened against the adapter The specified tightening tor ques must be observed see Fig 6 page 10 and Fig 7 page 11 Fig 6 Adjustment of the adapter tightening torque M10 locking screw 25 Nm supporting tube Ø 50 mm hexag...

Page 25: ...the air termination rod adapter is always aligned in parallel to the outer edge of the roof see Fig 7 page 11 tripod supporting tube Ø 50 mm 3200 mm long round 2x M8 locking screw s 15 Nm StSt air termination tip Ø 10 mm 1000 mm round Fig 7 Tripod adapted to a roof pitch of max 10 max 10 aligned in parallel ...

Page 26: ...ion systems are installed outside of Germany the country specific requirements concerning wind zones wind speeds must be fulfilled The zone dependent wind load building height and local conditions detached building building in open terrain or building surrounded by other buildings must be taken into account to calculate the actual wind load to be expected When designing isolated air termination rods...

Page 27: ...7 NOTES ...