INSTALLATION & MOUNTING OF THE HEATER

This appliance is an infrared heater dedicated exclusively to housing heating, as recommended below. 

The Degxel™ heaters can be installed in all interior parts of the housing.

The location should be chosen taking into account several parameters 

Heater maintenance and cleaning

Mounting and fixing the heater to a wall or ceiling

For your safety, the heater surface must be completely cold before dusting it off. It is forbidden to use any product 

like trichlorethylene solvents, abrasives, corrosives or similar products to clean the heater. It is forbidden to use 

water to clean the heater. Use a dry cloth to clean the front of the panel.

Follow carefully the installation instructions described in the separate manual supplied with your heater. Any 

installation not complying the instructions makes the warranty and manufacturer’s liability not applicable. If you 

feel not being able to achieve a proper installation, call a professional.

   Before connecting the appliance check that no anomalies are shown.

   The installation and operation must be performed by a responsible adult having no physical or mental disability. 

The heater shouldn’t be in any case left within the reach of children before, during or after installation. Make sure 

that small children cannot reach the heater once installed.

   Basically, the connection of the heater requires no electrical manipulation. Simply plug the appliance into a 

standard outlet. In case you want to hide the power cable behind the heater, call a professional.  

   Never pull the power cable and do not hang the unit by the cable. The cord should not be tied or wrapped. 

Take care so that the power cord is never in contact with sharp or hot surfaces so that it is never damaged.

   Never cover the appliance during use to avoid any risk of fire.

   Always observe a minimum distance of 25 mm between the heater and the supporting wall. If you follow the 

installation instructions and the original equipment, this distance is automatic.

   Only the heater frames provided by the manufacturer ensure your complete safety of use. Never replace the 

original frame and do not attempt to add another frame.

    The heater must be installed on an open façade (limiting the number of immediate obstacle) allowing the infra-

red radiation to deploy with an angle as wide as possible to reach a maximum of objects (walls, ceiling, floor, etc.). 

Always observe a minimum distance of 20 cm between the heater and any object lying above, beside or below. 

And a minimum distance of 40 cm in front of the heater.

    Make sure the front of the wall (for hanging the heater) is flat and solid in its structure (so there is no risk of 

degradation or crumbling, therefore unhooking). If in doubt, call a professional.

Overview

Summary of Contents for 1000W

Page 1: ... heater Temperature regulation and control Guarantee Page 2 Page 3 Page 4 Page 6 SUMMARY IMPORTANT Before use read this manual carefully and keep it for later use OPERATING INSTRUCTIONS For Infrared Heaters Metal Mirror Glass Picture Towel heaters Degxel Heaters All rights reserved www degxel com ...

Page 2: ...the plug with wet hands Keep the appliance packaging out of the reach of children Plastic bags carry the risk of suffocation If the appliance requires an electrical modification of your installation contact a professional To avoid the risk of fire do not cover in any case the heating unit The cord should not be tied or wrapped The surface temperature can reach 100 C To avoid burns it is forbidden ...

Page 3: ...s For more information about IR www foxof com Your Degxel heater Heating elements mesh composed of an alloy of copper and nickel Front metal sheet covered with a specific emissive powder Adding an ESG Securit glass depending on the model Technology heating by far infrared radiation Radiator surface temperature 90 C 110 C according to AC voltage 220 240V IP code IP45 IEC Protection class Class 1 Po...

Page 4: ...ation Make sure that small children cannot reach the heater once installed Basically the connection of the heater requires no electrical manipulation Simply plug the appliance into a standard outlet In case you want to hide the power cable behind the heater call a professional Never pull the power cable and do not hang the unit by the cable The cord should not be tied or wrapped Take care so that ...

Page 5: ...ate must be upward Drill holes on the spotted locations of the depth of the wall plugs Insert the wall plugs with a hammer Place the mounting plates on the wall or the ceiling and then insert the screws into the wall plugs Perform a maximum suitable tightening without rotating the wall plug itself Before placing the heater on the mounting plates make sure that the 4 white plastic pads located at 4...

Page 6: ...e refer to the manufactur er s manual supplied with the appliance Before any intervention on an electric equipment make sure the current of your habitation is cut off at the level of the switchboard Do make the electrical interventions by suitably qualified professionals The radio socket is suitable to start or stop the operation of the heater into which it is plugged The radio thermo stat allows ...

Page 7: ... scroll wheel until you reach the desired temperature Wait approximately 1 minute for the socket to trigger the heater Once the desired temperature is reached the thermostat sends the order to the socket to stop the heater Resetting the thermostat socket loss of connection If you were to restart the setting loss of connection power failure etc you would have to reset the socket To do that press at...

Page 8: ...wheel G Select the desired temperature with the scroll wheel G and confirm the choice by pressing it Repeat this procedure until all temperature phases are recorded until the end of the chosen period When you are satisfied with the settings do not touch the thermostat for 1 minute The home page will be displayed For further information refer to the manual supplied with the appliance By default you...

Page 9: ... note that the white box delivered with the receiver is useless for your config uration do not use it Using a wire cutter cut off free and stripp the 3 wires N Neutral Blue L Live Brown E Earth Ground Yellow Green As indicated on the diagram below the Neutral N wire from source has 2 departures divided in 2 parts Use a domino or a wago terminal to make 2 departures from the Live L and 2 departures...

Page 10: ...displayed briefly On the room thermostat press button Press The room thermostat will then send a radiowave configuration message and the icon will This step is also described in the following video www degxel co uk tutorial Do not hesitate to consult it if you have operating problems In order for the thermostat to communicate with the heater it s necessary to perform this step Without the coupling...

Page 11: ...Naturally the heater takes time to heat you need to wait 2 3 minutes to feel its surface heated it still doesn t work possible causes The first step has not been performed has not been performed correctly or the connection is incorrect If despite your trials the heater is not turned on by the thermostat it may be that the receiver or the thermostat is in an unstable mode Reset the receiver and the...

Page 12: ... on www degxel com To contribute to the environment preservation do not dispose of the device and its accessories in a trash can place them in a recycling point 1 Make sure you have read this manual before opening an after sale service record 2 Go directly to our website www degxel com and select your language 3 Using your ordering data order number retailer serial number explain your malfunction ...

Reviews: