ATTENTION!
Ensure a greatest possible clamp surface using the MTH-clamps. The MTH-clamp has to slide
along inside the aluminium profile towards the base frame until the bolt contacts the base frame.
The MTH-clamp must be in parallel to the longitudinal beam.
DEGER systems D80 and D100
The aluminium profiles are fastened with one MTH-clamp to each of the longitudinal beams from the outside.
Tightening torque: 35 Nm
DEGER systems D25H and D60H
The aluminium profiles are fastened with two MTH-clamp to each of the longitudinal beams from inside and
outside.
Tightening torque: 35 Nm
6.3
Further preparation
1.
Take the MLD-control out of the rotating head and fasten
it temporarily to the front of the rotating head.
2.
Apply the sticker "Access for unauthorized persons
prohibited!" so that is well visible on the mast at mid-
height.
MTH-clamp M10
M10x35 bolt
Sliding nut M10
Slide the MTH-clamp
towards the longitudinal
beam, until the bolt
thread matches
Additional
MTH-clamp
for D60H