Note.This appliance is supplied ex-
factory with jets and air settings for use 
with LPG gas only. 
 
Safety compliance with local 
requirements. 
 
Installer’s details are to be filled in on 
page 24 of this book 
 
 
Temporary installation 
 

Flexible hose connection from the gas 
appliance to the cylinder can be made . 
Ensure that pipe clamps are tightened 
correctly and are of good quality. 
 

x

Flexible hose 

- Not supplied. 

Any hose that is used to connect the 

stove to the gas system shall comply with 
SANS 1156-2 or BS 3212. 

x

Gas cylinder 

- Not supplied. 

For best results we recommend that gas 

cylinders with a minimum capacity of 19kg 
be used. 

x

Regulator

 - Not supplied. 

A 2.8-3.0 kPa LPG gas regulator which 

complies with SANS 1237 must be used. 

 

 

Permanent installation 
 
Important information for the user 
 
This appliance may only be installed by a  
registered LP Gas installer.  All registered 
installers are  issued with a card carrying 
their registration number.   
 
Ask to be shown this card before 
allowing the installation  to commence 
and make a note of the installer QCC 
number on page 24 of this book.  
 

Upon completion  of the installation, the 
installer is required to explain the operational 
details of the appliance together with the 
safety instructions. You will be asked to sign 
acceptance of the installation and be 
provided with a completion certificate. You 
should only sign  for acceptance when the 
installation is completed to your satisfaction.  
 

Failure to comply with the above will 
render the warranty invalid. 
 
Note:  
 
Your invoice is required in the event  of 
you wishing to make a warranty claim.  

Summary of Contents for DHG131

Page 1: ...e text and illustrations in this manual are subject to change without notice Record in the space below the listed information for future reference The serial number is on the serial label located on t...

Page 2: ...n on how to operate and care for your appliance to gain the maximum benefit from it We trust you will enjoy years of trouble free use EXPLANATION OF SYMBOLS Throughout this User Manual the following s...

Page 3: ...staller 10 Important information for the user 11 Electrical connection 12 Gas connection 12 Leakage control 13 Final check 14 Gas conversion 14 Package information 15 Future transportation 15 Disposin...

Page 4: ...cations text and illustrations in this manual are subject to change without notice Figures in this manual are schematic and may not match your appliance exactly Important Read these instructions for u...

Page 5: ...470 mm Burners Rear left Rapid burner Power 2900 W Front left Auxiliary burner Power 1000 W Front right Normal burner Power 2000 W Rear right Normal burner Power 2000 W Middle Wok Burner Power 3300 W...

Page 6: ...using alcoholic drinks in your dishes Alcohol evaporates at high temperatures and may cause a fire since it can ignite when it comes into contact with hot surfaces x Do not use the appliance for heati...

Page 7: ...itchen is well ventilated keep natural ventilation holes open or install a mechanical ventilation device mechanical extractor hood Prolonged intensive use of the appliance may call for additional vent...

Page 8: ...e safety of the occupants in the room in which the appliance is installed Intended use This appliance is designed for domestic use Commercial use will void the warrantee CAUTION This appliance is for...

Page 9: ...iance is designed for installation in a domestic worktop A safety distance must be left between the appliance and the kitchen walls and furniture See figure overleaf values in mm x This appliance can...

Page 10: ...Ventilation opening Smaller than 5 m3 min 100 cm2 5 m3 to 10 m3 min 50 cm2 Greater than 10 m3 not required In the cellar or basement min 65 cm2 Important information for the installer This appliance m...

Page 11: ...ich complies with SANS 1237 must be used Permanent installation Important information for the user This appliance may only be installed by a registered LP Gas installer All registered installers are i...

Page 12: ...ng any work on the gas installation please shut off the gas supply x Gas adjustment conditions and values are stated on labels or on type label Your appliance is adjusted for LPG gas Connecting the ga...

Page 13: ...gure Make sure the putty is filled on the base cover contours 5 Turning the hob again align and place it on the counter 6 Secure your hob to the counter by using the clamp and the screws supplied min...

Page 14: ...e flow rate adjustment screw For LPG Butane Propane turn the screw clockwise For natural gas you should turn the screw counter clockwise once The normal length of a straight flame in the reduced posit...

Page 15: ...general appearance of your appliance for any damages that might have occurred during transportation Disposing of the old product Dispose of the old appliance in an environmentally friendly manner Refe...

Page 16: ...to 4 times x Select the burner which is most suitable for the bottom size of the pot to be used Always select the correct pot size for your dishes Larger pots require more energy Initial use First cle...

Page 17: ...ut a pot pan or saucepan on it will cause damage to the appliance Turn off the cooking zones after cooking is complete x As the surface of the appliance can be hot do not place plastic and aluminum ve...

Page 18: ...Do not press the knob for longer than 15 seconds if there was no ignition Wait for one minute and then repeat the ignition process Wok burner As a counter measure against blow out due to fluid overflo...

Page 19: ...iance to cool down before you clean it Sugar based foods such as thick cream and syrup must be cleaned promptly without waiting the surface to cool down Otherwise glass ceramic surface may be damaged...

Page 20: ...d remove the pot stands burner caps and burner bodies 1 Insert the socket into the central tube of the burner so that it locates over the brass gas jet at the bottom of the tube 2 Gently loosen the br...

Page 21: ...The lighting procedure has not been followed correctly Follow the correct lighting procedure The flame is yellow Pots and pans are stained The burners are dirty or wet Clean dry the burner components...

Page 22: ...Block A1 Old Mutual Industrial Park Cnr D F Malan Drive Moot Str Hermanstad 0082 Tel 012 377 8300 Pretoria Service defy co za Sub Saharan Africa Service Agents ZAMBIA SOUTHGATE INVESTMENTS LTD Plot 16...

Page 23: ...nties that the purchaser takes due care and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating instructions connection to incorrect voltages and subjection t...

Page 24: ...uct at www defy co za Installer s details to be recorded below INSTALLER S NAME AND COMPANY INSTALLER S REGISTRATION NUMBER HAVE YOU RECEIVED A WRITTEN COMPLETION CERTIFICATE HAS THE INSTALLER EXPLAIN...

Reviews: