13
fireplace insert. Lifting upwards is a normal method for
the opening of guillotine doors.
6.3.
DAMPING
Damping is executed by the closing inflow of primary air. In such
case, you should wait until the fuel completely burns out in a natural
way.
If it is necessary to quickly damp a flame you should charge the
furnace chamber with dry sand or ash. It is not allowed to damp a flame
by pouring it with water because it may damage components of the
equipment.
After a longer break in equipment’s operation, you
should check the flow capacity of the flue.
7.
CLEANING AND MAINTENANCE
All operations related to cleaning of all components
should be carried out when the fireplace is completely
cold. It is required to use protective gloves.
It is a good practice to ensure good ventilation of the
room during the cleaning of the fireplace.
7.1.
BASIC OPERATIONS AND CLEANING BY THE USER
Any service and maintenance works are to be carried out with me-
ticulous care and only by adults familiarized with this manual. The fire-
place insert should not be cleaned in the presence of children.
Any service and maintenance works are to be carried
out with meticulous care and only by adults familiarized
with this manual. The dry fireplace insert should not be
cleaned in the presence of children.
Protective gloves, glasses and headgear are to be worn
to operate the equipment.
7.1.1.
CLEANING BEFORE EACH STARTING
Prior to every successive start-up of the equipment, the ash con-
tainer should be cleaned and emptied, handling the ash with due care.
Remove grate, then ash container (picture below) using handles, and
remove the remaining dust. Dust can be removed using vacuum
cleaner only if it is completely cold. Use vacuum cleaner adapted to
removing the particles of a specified size for this purpose.
Re-install the ash container below the grate after the cleaning,
making sure that its position is correct.
Picture 17. Removal of grate and ash-pan for emptying purposes.
7.1.2.
WINDOW PANEL CLEANING
It is recommended using a dry brush to clean the ceramic glass. If
the contamination is significant to use suitable cleaning agent spray
and spray little amount and then clean the window panel with a cloth.
Picture 18. Location of locks allowing the opening of the doors in hinged
position for DEFRO HOME INTRA SLIM G.
Picture 19. View of fireplace insert DEFRO HOME INTRA SLIM G with
doors in the lifted position.
Picture 20. Location of locks allowing the opening of the doors in hinged
position for DEFRO HOME INTRA BP SLIM G.