6.2.

 

FIRST START-UP AND OPERATION 

Prior firing up you should set a slider of air inflow adjustment to 

the maximum opening (marking on the handle, presented on figure 31). 

Then, open the doors of the insert and place fire starter and fragmented 

wood, then charge approx. 1 kg of dry hardwood, fire up and close the 

doors. 

 

It is forbidden to use other materials than described

in this manual for firing up, in particular flammable

chemicals such as: oil, petrol, solvents and others. 

After firing up refill combustion chamber with wood, placing fuel in 

a way that reasonably fills the combustion chamber. Recommended 

single fuel charge is given in table 2. Method of fuel laying is shown on 

figure 32  

 

Picture 31

.

 Setting of slider for air inflow adjustment 

 

Picture 32

.

 Method of fuel arrangement during firing up  

The intensity of the fuel combustion process should be adjusted by 

proper setting of the air supply adjustment slider. Doors of fireplace 

insert should be closed during operation of the fireplace insert. 

The odour of paint from the body will be released during the first 

several hours of combustion. This is completely normal. You should 

strongly vent the room at that time. Check tightness of joints once again 

when fuel is completely burned out and equipment has been cooled 

down. 

 

Housing components will be very hot during operation.

You must exercise caution. 

You should control the level of filling of the container with ash. 

Overfilling of container results in lack of cooling of the grate and limits 

air supply for combustion. To empty the container you should damp a 

fireplace, close inflow of air for combustion and wait until surface and 

parts of the fireplace insert cool down. Then open doors of the insert, 

remove the grate and take out the container. Remove ash from con-

tainer and re-install in the body of the insert. It is recommended to 

empty ash container prior to each successive start-up of the equipment. 

Do not fill the furnace completely with wood. The charge should 

not exceed 1/3 of the volume of the combustion chamber. You should 

use only hardwood (recommended beech, oak, hornbeam) of low mois-

ture content (below 20%). 

During combustion the doors should be opened only when the fuel 

is being added. Prior to adding the wood you should wait until flames 

fall down and charge is completely burnt out leaving an igniting layer of 

glow. After firing up refill combustion chamber with wood, placing fuel 

in a way that reasonably fills the combustion chamber for the combus-

tion period expected by the user based on personal experience. The 

intensity of the fuel combustion process should be adjusted by proper 

setting of the air supply adjustment slider. 

During operation doors in DEFRO HOME INTRA fireplace inserts 

in G version can be only opened by lifting. Hinged door opening for this 

versions is intended only for service purposes and it should not be 

opened during combustion.  

 

Never stand in front of the fireplace insert door while 

opening. Burn risk. 

Hinged doors should not be opened during combustion 

in case of G version of the DEFRO HOME INTRA fire-

place insert. Lifting upwards is a normal method for the 

opening of guillotine doors. 

 

Only one door of fireplace in case of T version may be 

opened during combustion! 

6.3.

 

DAMPING 

Damping is executed by the closing inflow of INTRAry air. In such 

case you should wait until the fuel completely burns out in a natural 

way. 

If it is necessary to quickly damp a flame you should charge fur-

nace chamber with dry sand or ash. It is not allowed to damp a flame 

by pouring it with water because it may damage components of the 

equipment. 

 

After a longer break in equipment’s operation you 

should check flow capacity of the flue. 

7.

 

CLEANING AND MAINTENANCE 

 

All operations related to cleaning of all components 

should be carried out when the fireplace is completely 

cold. It is required to use protective gloves. 

 

It is a good practice to ensure good ventilation of the 

room during cleaning of the fireplace. 

7.1.

 

BASIC OPERATIONS AND CLEANING BY THE USER. 

Any service and maintenance works are to be carried out with 

meticulous care and only by adults familiarized with this manual. The 

fireplace insert should not be cleaned in the presence of children. 

 

Any service and maintenance works are to be carried 

out with meticulous care and only by adults familiarized 

with this manual. The dry fireplace insert should not be 

cleaned in the presence of children.  

Protective gloves, glasses and headgear are to be worn 

to operate the equipment. 

7.1.1.

 

CLEANING BEFORE EACH STARTING 

Prior to every successive start-up of the equipment the ash con-

tainer should be cleaned and emptied, handling the ash with due care. 

closed

open

Summary of Contents for INTRA LA

Page 1: ...operating manual fireplace DEFRO HOME INTRA series model XSM SM ME LA XLA version C T G BL BP MINI translation of original operating manual issue 19 June 2020...

Page 2: ...przypadku odst pienia w asno ci innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME INTRA Fireplace if its construction has been changed without...

Page 3: ...py of the War ranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwisowe Ruda Strawczy ska 103a 26 067 Strawczyn fax 0048 41 303 91 31 serwis defro pl By sending back your Warranty Card...

Page 4: ...1 Basic operations and cleaning by the user 17 7 1 1 Cleaning before each starting 17 7 1 2 Window panel cleaning 18 7 1 3 Doors gaskets 19 7 1 4 Furnace chamber 19 7 1 5 Flue 19 7 2 Periodic inspecti...

Page 5: ...marked in this way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the legal standards applicable in the give...

Page 6: ...ION In case of any problems you should contact sales out let or qualified personnel authorized by DEFRO Re quest original spare parts if the repair is necessary Use only fuel with properties compatibl...

Page 7: ...s for flue gas afterburning system 14 are additionally located in the rear wall of the furnace chamber Flue gases are removed to the chimney through a flue located in the upper wall of the fireplace i...

Page 8: ...re 7 Dimensions of fireplace insert DEFRO HOME INTRA LA Picture 8 Dimensions of fireplace insert DEFRO HOME INTRA SM G 679 630 1430 535 1024 521 454 135 246 577 500 67 35 246 1430 535 846 795 1024 265...

Page 9: ...cture 11 Dimensions of fireplace insert DEFRO HOME INTRA SM BP Picture 12 Dimensions of fireplace insert DEFRO HOME INTRA ME BP 1027 744 503 778 106 356 1460 930 552 396 1460 1118 1195 912 503 946 552...

Page 10: ...BP MINI G version Picture 15 Dimensions of fireplace insert DEFRO HOME INTRA SM BP in G version Picture 16 Dimensions of fireplace insert DEFRO HOME INTRA ME BP in G version 697 628 430 373 465 451 41...

Page 11: ...insert DEFRO HOME INTRA ME T in G version 1416 255 244 245 135 535 679 649 507 386 57 535 531 67 186 36 630 630 197 125 464 37 507 386 57 37 88 1442 504 248 135 553 860 779 507 396 88 535 629 67 15 17...

Page 12: ...imensions of fireplace insert DEFRO HOME INTRA XSM C in G version 1407 245 135 535 1017 987 842 386 965 197 598 67 465 125 246 244 57 37 842 386 57 37 1442 504 247 135 553 1195 1114 842 396 125 535 56...

Page 13: ...009 197 Table 1 Technical data of fireplace Parameters DEFRO HOME PRIMA Parameter Unit XSM SM ME LA XLA Nominal power kW 8 10 13 16 22 Flue size mm 150 200 200 200 250 Efficiency 80 9 80 1 80 80 1 80...

Page 14: ...icle s platform by means of belts wedges and wooden blocks Fireplace insert DEFRO HOME INTRA should be in stalled in compliance with the requirements of the cur rently applicable standards and legal r...

Page 15: ...fireplace insert power over 15 kW grille cross section min 800 1200 cm2 and more Air can be supplied from adjacent rooms provided that they are equipped with external air supply and they are not inten...

Page 16: ...t should not exceed 4 Chimney or individual smoke duct should meet the following require ments be resistant tocombustion products water proof and suitably insulated in compliance with conditions of us...

Page 17: ...you should wait until flames fall down and charge is completely burnt out leaving an igniting layer of glow After firing up refill combustion chamber with wood placing fuel in a way that reasonably fi...

Page 18: ...pped with locks on top and bottom of the frame on its left side figure 36 Picture 34 Location of locks allowing opening of the doors in hinged position for DEFRO HOME INTRA G Picture 35 View of firepl...

Page 19: ...g on moisture content and type of wood used 7 1 5 FLUE In compliance with applicable regulations you should clean the flue two times a year The flue should be cleaned by a chimneysweep company and thi...

Page 20: ...re 39 Window panel dismantling from doors 7 5 DISASSEMBLY OF DEFLECTOR Location of the deflector in the fireplace is presented in picture 1 1 Dismount the deflector blockades from both sides of the fi...

Page 21: ...TRA G They are intended only for use by the qualified service of the manufacturer to ensure access during adjust ment and maintenance works Access to these holes is possible after dismantling cladding...

Page 22: ...oor and cleaning holes tightly to cut off air supply due to lack of air the fire will eventually stop check the whole chimney channel for any cracks which might result in fire spread to the rooms prep...

Page 23: ...ately after a fault has been found and no later than after 14 days 12 Any fault is to be registered with the Guarantor Ruda Straw czy ska 103a 26 067 Strawczyn by sending a complaint sheet contained i...

Page 24: ...apply 12 1 WARRANTY CONDITIONS 48H SERVICE 1 The 48h Service program covers equipment manufactured by DEFRO Sp z o o Sp k 2 Any complaints are to be made at a sales outlet or directly at the Company o...

Page 25: ...at the equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation m...

Page 26: ...26 14 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10...

Page 27: ...at the equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation m...

Page 28: ...28...

Page 29: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of co...

Page 30: ...30...

Page 31: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of co...

Page 32: ...32...

Page 33: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of co...

Page 34: ...34...

Page 35: ...35 19 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of a chimneysweep date stamp and signature of a chimneysweep...

Page 36: ...2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 27 mg m3 Commission Regulation EU 2015 1185 NOx emission in combustion products 166 mg m3 Commission Regulati...

Page 37: ...Performance Technical specification CO emission in combustion products 0 08 13 O2 950 mg m3 13 O2 PN EN 13229 2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products...

Page 38: ...ission in combustion products 0 06 13 O2 798 mg m3 13 O2 PN EN 13229 2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 24 mg m3 13 O2 Commission Regulation EU...

Page 39: ...N EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 63 mg m3 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 158 mg m3 13 O2 Commission Re...

Page 40: ...05 PN EN 13229 2002 A2 2006 OGC emission in combustion products 69 mg m3 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 111 mg m3 13 O2 Commission Regulation EU 2015 1185...

Page 41: ...a 103A PARAMETERS OF THE EQUIPMENT J M MODEL IDENTIFICATION DEFRO HOME INTRA XSM DEFRO HOME INTRA XSM CG Energy efficiency class Direct thermal power kW 8 6 Indirect thermal power kW N A Energy effici...

Page 42: ...RA SM BL DEFRO HOME INTRA SM BP G DEFRO HOME INTRA SM BL G DEFRO HOME INTRA SM BP MINI DEFRO HOME INTRA SM BL MINI DEFRO HOME INTRA SM BP MINI G DEFRO HOME INTRA SM BL MINI G DEFRO HOME INTRA SM T DEF...

Page 43: ...FRO HOME INTRA ME G DEFRO HOME INTRA ME BP DEFRO HOME INTRA ME BL DEFRO HOME INTRA ME BP G DEFRO HOME INTRA ME BL G DEFRO HOME INTRA ME T DEFRO HOME INTRA ME T G DEFRO HOME INTRA ME C G Energy efficie...

Page 44: ...THE EQUIPMENT J M MODEL IDENTIFICATION DEFRO HOME INTRA LA DEFRO HOME INTRA LA G DEFRO HOME INTRA LA T DEFRO HOME INTRA LA T G Energy efficiency class Direct thermal power kW 16 5 Indirect thermal pow...

Page 45: ...Strawczy ska 103A PARAMETERS OF THE EQUIPMENT J M MODEL IDENTIFICATION DEFRO HOME INTRA XLA G Energy efficiency class Direct thermal power kW 22 4 Indirect thermal power kW N A Energy efficiency Inde...

Page 46: ...46...

Page 47: ...47...

Page 48: ...509 702 720 509 577 900 DEFRO Sp ka z ograniczon odpowiedzialno ci Sp ka komandytowa 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro...

Reviews: