Defro Home INTRA LA Operating Manual Download Page 14

14

 

 

4.4.

 

FUEL PARAMETRS 

A fireplace insert is intended for combustion of wood from decidu-

ous trees (oak, hornbeam, ash, beech) with a moisture content below 

20% (wood seasoned in proper conditions for at least 2 years). The 

maximum length of chunks is given in table 1. It is allowed to use wood 

briquette.  

It is not allowed to use wet wood (extensive contamination of fire-

place and soot emission and a decrease of furnace energy efficiency).  

It is forbidden to use all other fuels, min. coal, softwood from conif-

erous trees, wood from tropical trees and any liquid fuels. 

It is forbidden to combust all types of litter and wood wastes. Firing 

with inadmissible materials in the fireplace may result in damage to the 

fireplace and life and health hazard for the users (toxic flue gas from 

chemicals). 

 

Use of bad quality fuel or incompatible with the above-

mentioned recommendations would cause irregulari-

ties in the operation of the equipment and can lead to 

loss of warranty and decline of the liability for the 

product.  

The fireplace is not a furnace intended for combustion

of wastes and forbidden fuels cannot be combusted in

it. 

Wood should be seasoned minimum two years. Firing

with wet wood, with low calorific value, decreases the

efficiency and has an adverse influence on dry stove

lifetime. 

It is not recommended to use softwood and resinous

woods as a fuel. It causes intensive smoke concentra-

tion and the necessity to clean the equipment and flue

more often. 

It is forbidden to combust coal, wood from tropical

trees, chemical products, liquid fuels etc., e.g. oil, alco-

hol, petrol, naphthalene, laminated, impregnated 

boards etc., paper, cardboards, old clothes, wastes. 

DEFRO sp. z o.o. Sp. k. does not accept liability for dam-

age caused or improper burning of fuel if the fuel used

is prohibited. 

4.5.

 

SPARE PARTS 

To obtain information on the availability of spare parts for fireplace 

insert or inquiries about equipment servicing please contact with DE-

FRO Service Center or Authorized DEFRO Service. 

 

DEFRO sp. z o.o. Sp. k.  
Service Centre 
Ruda Strawczy

ń

ska 103a 

26-067 Strawczyn

 

 

Fax 0048 41 303 91 31 

@

 

[email protected]

 

5.

 

TRANSPORT AND INSTALLATION 

5.1.

 

TRANSPORT AND STORAGE 

The fireplace is delivered on a pallet, foil-wrapped and is fully as-

sembled. It is recommended to transport fireplace insert, in such pack-

ing condition, as close as a possible target location for installation, what 

will minimize the possibility of damage to device housing. 

All remaining parts of the packing should be removed in such a 

way that it will not pose any hazard for people and animals. 

 

The fireplace is to be transported in a vertical position! 

Appropriate lifts are to be used for lifting and lowering the fireplace 

insert. For transport, the fireplace insert is to be secured against mov-

ing and tilting on a vehicle’s platform by means of belts, wedges and 

wooden blocks. 

 

Fireplace insert DEFRO HOME INTRA should be in-

stalled in compliance with the requirements of the cur-

rently applicable standards and legal regulations and 

detailed regulations of the target country. In Poland 

these conditions are regulated by the Regulation of the 

Minister of Infrastructure of 12 April 2002 on technical 

conditions which should be fulfilled by buildings and its 

location. (Journal of Laws no. 75 of 2002 item 690 as 

amended) and Polish Standard PN-EN 13229:2002 Inset 

appliances including open fires fired by solid fuels. Re-

quirements and tests. 

A fireplace insert is to be stored in a non-heated room, under a roof 

and with efficient ventilation. 

Prior to installation it is to be determined if all parts have been de-

livered and if they are in good technical condition. 

5.2.

 

WORKING ENVIRONMENT 

Fireplace insert should be installed in a suitable location allowing 

opening of the doors and carrying out regular maintenance works. The 

environment should be: 

 

adapted to operating conditions, 

 

equipped with power supply 230V/50Hz, 

 

equipped with a suitable flue gas exhaust system, 

 

equipped with an external ventilation system, 

 

equipped with an earthing system with CE certificate. 

Correct setting of the insert is necessary to obtain the satisfactory 

heating level of the residential unit. Prior to assembly it is necessary to 

select a suitable position for stove installation. Check minimum safe 

distances from materials susceptible to heat or inflammable materials 

such as load-bearing walls and other walls or wooden components, fur-
niture etc. Exemplary installation of fireplace insert is presented on 

picture 27. 

Installation of the fireplace insert should observe the following 

safety rules: 

 

minimum distance 80 mm from side and rear of the non-flam-

mable materials, 

 

minimum distance 400 mm from side and rear of the medium 
inflammable materials, 

 

minimum distance 800 mm from the front wall, where the me-

dium inflammable materials cannot be located. 

 

objects made of highly inflammable materials should be lo-
cated in distance minimum 2000 mm from the furnace 

If it is not possible to maintain the above indicated distances then 

you should apply process and building measures to avoid fire hazards. 

In case of contact with wooden wall or wall made of other inflammable 

material it is appropriate to insulate flue gas discharge pipe. 

 

In the case of the floor made of inflammable materials it 

is appropriate to prepare a plane protecting the floor 

and execute protection in accordance with the stand-

ards applicable in the given country. 

Fireplace insert should be located on a substrate with suitable 

load-bearing capacity. In accordance with the Polish Standards each 

square meter of the floor slab in the single-family building should trans-

fer a load of 150 kg. If this condition is fulfilled the fireplace insert man-

ufactured by DEFRO can be installed without needing to reinforce the 

floor slab.  

Summary of Contents for INTRA LA

Page 1: ...operating manual fireplace DEFRO HOME INTRA series model XSM SM ME LA XLA version C T G BL BP MINI translation of original operating manual issue 19 June 2020...

Page 2: ...przypadku odst pienia w asno ci innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME INTRA Fireplace if its construction has been changed without...

Page 3: ...py of the War ranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwisowe Ruda Strawczy ska 103a 26 067 Strawczyn fax 0048 41 303 91 31 serwis defro pl By sending back your Warranty Card...

Page 4: ...1 Basic operations and cleaning by the user 17 7 1 1 Cleaning before each starting 17 7 1 2 Window panel cleaning 18 7 1 3 Doors gaskets 19 7 1 4 Furnace chamber 19 7 1 5 Flue 19 7 2 Periodic inspecti...

Page 5: ...marked in this way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the legal standards applicable in the give...

Page 6: ...ION In case of any problems you should contact sales out let or qualified personnel authorized by DEFRO Re quest original spare parts if the repair is necessary Use only fuel with properties compatibl...

Page 7: ...s for flue gas afterburning system 14 are additionally located in the rear wall of the furnace chamber Flue gases are removed to the chimney through a flue located in the upper wall of the fireplace i...

Page 8: ...re 7 Dimensions of fireplace insert DEFRO HOME INTRA LA Picture 8 Dimensions of fireplace insert DEFRO HOME INTRA SM G 679 630 1430 535 1024 521 454 135 246 577 500 67 35 246 1430 535 846 795 1024 265...

Page 9: ...cture 11 Dimensions of fireplace insert DEFRO HOME INTRA SM BP Picture 12 Dimensions of fireplace insert DEFRO HOME INTRA ME BP 1027 744 503 778 106 356 1460 930 552 396 1460 1118 1195 912 503 946 552...

Page 10: ...BP MINI G version Picture 15 Dimensions of fireplace insert DEFRO HOME INTRA SM BP in G version Picture 16 Dimensions of fireplace insert DEFRO HOME INTRA ME BP in G version 697 628 430 373 465 451 41...

Page 11: ...insert DEFRO HOME INTRA ME T in G version 1416 255 244 245 135 535 679 649 507 386 57 535 531 67 186 36 630 630 197 125 464 37 507 386 57 37 88 1442 504 248 135 553 860 779 507 396 88 535 629 67 15 17...

Page 12: ...imensions of fireplace insert DEFRO HOME INTRA XSM C in G version 1407 245 135 535 1017 987 842 386 965 197 598 67 465 125 246 244 57 37 842 386 57 37 1442 504 247 135 553 1195 1114 842 396 125 535 56...

Page 13: ...009 197 Table 1 Technical data of fireplace Parameters DEFRO HOME PRIMA Parameter Unit XSM SM ME LA XLA Nominal power kW 8 10 13 16 22 Flue size mm 150 200 200 200 250 Efficiency 80 9 80 1 80 80 1 80...

Page 14: ...icle s platform by means of belts wedges and wooden blocks Fireplace insert DEFRO HOME INTRA should be in stalled in compliance with the requirements of the cur rently applicable standards and legal r...

Page 15: ...fireplace insert power over 15 kW grille cross section min 800 1200 cm2 and more Air can be supplied from adjacent rooms provided that they are equipped with external air supply and they are not inten...

Page 16: ...t should not exceed 4 Chimney or individual smoke duct should meet the following require ments be resistant tocombustion products water proof and suitably insulated in compliance with conditions of us...

Page 17: ...you should wait until flames fall down and charge is completely burnt out leaving an igniting layer of glow After firing up refill combustion chamber with wood placing fuel in a way that reasonably fi...

Page 18: ...pped with locks on top and bottom of the frame on its left side figure 36 Picture 34 Location of locks allowing opening of the doors in hinged position for DEFRO HOME INTRA G Picture 35 View of firepl...

Page 19: ...g on moisture content and type of wood used 7 1 5 FLUE In compliance with applicable regulations you should clean the flue two times a year The flue should be cleaned by a chimneysweep company and thi...

Page 20: ...re 39 Window panel dismantling from doors 7 5 DISASSEMBLY OF DEFLECTOR Location of the deflector in the fireplace is presented in picture 1 1 Dismount the deflector blockades from both sides of the fi...

Page 21: ...TRA G They are intended only for use by the qualified service of the manufacturer to ensure access during adjust ment and maintenance works Access to these holes is possible after dismantling cladding...

Page 22: ...oor and cleaning holes tightly to cut off air supply due to lack of air the fire will eventually stop check the whole chimney channel for any cracks which might result in fire spread to the rooms prep...

Page 23: ...ately after a fault has been found and no later than after 14 days 12 Any fault is to be registered with the Guarantor Ruda Straw czy ska 103a 26 067 Strawczyn by sending a complaint sheet contained i...

Page 24: ...apply 12 1 WARRANTY CONDITIONS 48H SERVICE 1 The 48h Service program covers equipment manufactured by DEFRO Sp z o o Sp k 2 Any complaints are to be made at a sales outlet or directly at the Company o...

Page 25: ...at the equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation m...

Page 26: ...26 14 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10...

Page 27: ...at the equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation m...

Page 28: ...28...

Page 29: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of co...

Page 30: ...30...

Page 31: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of co...

Page 32: ...32...

Page 33: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of co...

Page 34: ...34...

Page 35: ...35 19 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of a chimneysweep date stamp and signature of a chimneysweep...

Page 36: ...2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 27 mg m3 Commission Regulation EU 2015 1185 NOx emission in combustion products 166 mg m3 Commission Regulati...

Page 37: ...Performance Technical specification CO emission in combustion products 0 08 13 O2 950 mg m3 13 O2 PN EN 13229 2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products...

Page 38: ...ission in combustion products 0 06 13 O2 798 mg m3 13 O2 PN EN 13229 2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 24 mg m3 13 O2 Commission Regulation EU...

Page 39: ...N EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 63 mg m3 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 158 mg m3 13 O2 Commission Re...

Page 40: ...05 PN EN 13229 2002 A2 2006 OGC emission in combustion products 69 mg m3 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 111 mg m3 13 O2 Commission Regulation EU 2015 1185...

Page 41: ...a 103A PARAMETERS OF THE EQUIPMENT J M MODEL IDENTIFICATION DEFRO HOME INTRA XSM DEFRO HOME INTRA XSM CG Energy efficiency class Direct thermal power kW 8 6 Indirect thermal power kW N A Energy effici...

Page 42: ...RA SM BL DEFRO HOME INTRA SM BP G DEFRO HOME INTRA SM BL G DEFRO HOME INTRA SM BP MINI DEFRO HOME INTRA SM BL MINI DEFRO HOME INTRA SM BP MINI G DEFRO HOME INTRA SM BL MINI G DEFRO HOME INTRA SM T DEF...

Page 43: ...FRO HOME INTRA ME G DEFRO HOME INTRA ME BP DEFRO HOME INTRA ME BL DEFRO HOME INTRA ME BP G DEFRO HOME INTRA ME BL G DEFRO HOME INTRA ME T DEFRO HOME INTRA ME T G DEFRO HOME INTRA ME C G Energy efficie...

Page 44: ...THE EQUIPMENT J M MODEL IDENTIFICATION DEFRO HOME INTRA LA DEFRO HOME INTRA LA G DEFRO HOME INTRA LA T DEFRO HOME INTRA LA T G Energy efficiency class Direct thermal power kW 16 5 Indirect thermal pow...

Page 45: ...Strawczy ska 103A PARAMETERS OF THE EQUIPMENT J M MODEL IDENTIFICATION DEFRO HOME INTRA XLA G Energy efficiency class Direct thermal power kW 22 4 Indirect thermal power kW N A Energy efficiency Inde...

Page 46: ...46...

Page 47: ...47...

Page 48: ...509 702 720 509 577 900 DEFRO Sp ka z ograniczon odpowiedzialno ci Sp ka komandytowa 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro...

Reviews: