Defiant 747373 Use And Care Manual Download Page 8

 8

Operation (continued)

Setting the Sensor for Testing

When the “ON-TIME” switch is set to the “TEST” 
position, the light fixture will operate during the day 
or night. The light will stay on for 5 seconds after all 
motion is stopped.

 

Set the “ON-TIME” switch to the “TEST” 
position.

 

Set the “DUALBRITE” switch to the “OFF” 
position.

 

Turn the “RANGE” dial to the “MIN” position.

 

Aim the motion sensor (C) in the general 
direction of the area to be covered.

NOTE:

 The motion sensor will need to completely warm 

up (90 seconds) before beginning the setup process.

LAMP MODE

NORMAL   SOFT FLASH

ON-TIME

DUAL BRITE™

TEST  1  5  20

           MINUTES

OFF  3  6  DUSK TO

       HOUR     DAWN

MAX

MIN

RANGE

Adjusting the Motion Sensor 

Detection Zone

 

Turn on the circuit breaker or fuse and the light 
switch.

 

Perform a “walk test”. Walk in an arc across 
the front of the motion sensor (C).

 

Watch the light. The light will come on and the 
red LED will flash indicating motion has been 
detected.

 

Stop, wait for the light to turn off, and then 
begin walking again.

 

Continue this process until the detection zone 
has been established.

 

Adjust the sensor up, down, or side to side to 
change the motion sensor (C) detection zone.

Adjusting the RANGE Dial

 

To increase the detection zone, turn the 
“RANGE” dial toward the “MAX” position.

 

To decrease the detection zone, turn the 
“RANGE” dial toward the “MIN” position.

NOTE:

 The motion sensor (C) is more sensitive to motion 

moving across the front of the sensor. The motion sensor 
(C) is less sensitive to motion moving directly toward the 
front of the sensor.

NOTE:

 The higher the “RANGE” setting (sensitivity), the 

greater the possibility of false triggering. To reduce false 
triggering, rotate the “RANGE” control toward the “MIN” 
setting.

LAMP MODE

NORMAL   SOFT FLASH

ON-TIME

DUAL BRITE™

TEST  1  5  20

           MINUTES

OFF  3  6  DUSK TO

       HOUR     DAWN

MAX

MIN

RANGE

Adjusting the ON-TIME Switch

The “ON-TIME” switch determines the amount of time 
the light will stay on full bright after all motion has 
stopped.

 

Set the “ON-TIME” switch to the 1, 5, or 20 
minute position.

LAMP MODE

NORMAL   SOFT FLASH

ON-TIME

DUAL BRITE™

TEST  1  5  20

           MINUTES

OFF  3  6  DUSK TO

       HOUR     DAWN

MAX

MIN

RANGE

C

C

C

C

Summary of Contents for 747373

Page 1: ...sit us online to see our full line of products available for your home improvement needs Thank you for choosing Defiant USE AND CARE GUIDE MOTION SECURITY LIGHT Questions problems missing parts Before...

Page 2: ...tible surface within 3 ft 1 m WARNING Risk of fire Keep the bulbs at least 2 in 51 mm from combustible materials CAUTION Keep the motion sensor at least 1 in 25 mm away from the bulbs CAUTION Keep the...

Page 3: ...modes Test Auto Manual Bulb modes Security BulbSaver AlertFlash Time delay 1 5 20 minutes DualBrite timer Off 3 hours 6 hours dusk to dawn Pre Installation PLANNING INSTALLATION Before installing the...

Page 4: ...CC DD EE FF GG FRONT HH II Part Description Quantity AA Wire connector 3 BB Rubber plug 1 CC Mounting bolt 1 DD Mounting bracket screw 2 EE Mounting bracket screw 2 FF Mounting bracket screw 2 GG Gas...

Page 5: ...in the general direction of the desired light coverage and tighten the lock nuts 1 and the thumb screws 2 If needed lift the motion sensor C up and rotate it so the controls face the ground after ins...

Page 6: ...hanger II into one of the two small slotted holes on the mounting bracket HH Route the light fixture wires through the large holes in the gasket GG F R O N T FRONT 3 Wiring the Light Fixture CAUTION...

Page 7: ...at least 2 in 51 mm from combustible materials CAUTION Keep the sensor at least 1 in 25 mm away from the bulbs CAUTION Keep bulb holders 30 below horizontal to avoid water damage and electrical shock...

Page 8: ...urn off and then begin walking again Continue this process until the detection zone has been established Adjust the sensor up down or side to side to change the motion sensor C detection zone 5 Adjust...

Page 9: ...inue dimming until the light turns off AlertFlash FLASH Light flashes on then off twice before turning on full brightness Set the LAMP MODE to NORMAL SOFT or FLASH position LAMP MODE NORMAL SOFT FLASH...

Page 10: ...close to the same as a person s body heat Increase the RANGE setting The light comes on during the day The motion sensor may be installed in a relatively dark location The light fixture is operat ing...

Page 11: ...he same circuit as a motor transformer or fluorescent bulb Install the light fixture on a circuit without motors transformers or fluorescent bulbs The lights flash on and off Heat or light from the bu...

Page 12: ...roblems missing parts Before returning to the store call Defiant Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 866 308 3976 HOMEDEPOT COM Retain this manual for future use...

Page 13: ...nea completa de productos disponibles que necesita para el mejoramiento de su hogar Gracias por escoger Defiant GU A PARA EL USO Y CUIDADO LUZ DE SEGURIDAD POR MOVIMIENTO Tiene preguntas problemas o p...

Page 14: ...ies 1 m ADVERTENCIA Riesgo de incendio Mantenga las bombillas alejadas al menos 2 pulgadas 51mm de materiales combustibles PRECAUCI N Mantenga el detector de movimiento al menos a 1 pulgada 25mm aleja...

Page 15: ...Fases de la bombilla Seguridad ahorrador de bombilla destello de alerta Retardo de tiempo 1 5 20 minutos Temporizador DualBrite Apagado 3 horas 6 horas del crep sculo al amanecer Antes de la instalaci...

Page 16: ...FRONT HH II Pieza Descripci n Cantidad AA Capuch n para cable 3 BB Tap n de caucho 1 CC Tornillo de montaje 1 DD Tornillo del soporte de montaje 2 EE Tornillo del soporte de montaje 2 FF Tornillo del...

Page 17: ...al para la cobertura deseada de la luz y apriete las contratuercas 1 y los tornillos de mariposa 2 Si es necesario levante el detector de movimiento C y g relo de forma que los controles queden de car...

Page 18: ...agujeros peque os y ranurados del soporte de montaje HH Pase los conductores del aparato de luz por los agujeros grandes del empaque GG F R O N T FRONT 3 Cableado del aparato de luz PRECAUCI N No cor...

Page 19: ...ustibles PRECAUCI N Mantenga el detector de movimiento al menos a 1 pulgada 25 mm alejado de las bombillas PRECAUCI N Mantenga los porta bombillas inclinados 30 por debajo de la horizontal para evitar...

Page 20: ...luz se apague y luego empiece a caminar de nuevo Contin e este proceso hasta que la zona de detecci n haya sido establecida Ajuste el detector hacia arriba abajo o a los lados para cambiar la zona de...

Page 21: ...asta que se apaga Destello de alerta AlertFlash FLASH La luz destella y luego se apaga esto dos veces antes de encenderse con todo su brillo Coloque la FASE L MPARA en las posiciones NORMAL SOFT o FLA...

Page 22: ...r est cer cana al calor corporal de una persona Aumente la calibraci n del alcance RANGE La luz se enciende durante el d a El detector de movimiento puede estar instalado en un sitio relativamente osc...

Page 23: ...r por un interruptor de pared est ndar de encendido apagado El aparato de luz est en el mismo circuito que un motor transformador o tubo fluorescente Instale el aparato de luz en un circuito sin motor...

Page 24: ...s o piezas faltantes Antes de devolverlo a la tienda llame a Servicio al Cliente de Defiant de 08 a m 7 p m EST Lunes Viernes 09 a m 6 p m EST s bado 1 866 308 3976 HOMEDEPOT COM Guarde este manual pa...

Reviews: