background image

Operating instructiOns

adiabatic Humidifiers

2560479  

en

  1108

Defensor pH28/pH28a

Summary of Contents for PH28

Page 1: ...Operating instructions Adiabatic Humidifiers 2560479 EN 1108 Defensor PH28 PH28A...

Page 2: ......

Page 3: ...fan step 21 5 4 3 Selecting the operating mode 22 5 4 4 Switching the buzzer on and off 22 5 4 5 Calling timer level 23 5 5 Program operation 24 5 5 1 Calling the timer level 24 5 5 2 Activating Deact...

Page 4: ...tions in the operating instructions 1 Introduction We thank you for having purchased an air purifier air humidifier Defensor PH28 or PH28A The air purifier air humidifier Defensor PH28 PH28A incorpora...

Page 5: ...his operating instructions in a safe place where it can be immediately accessed If the equipment changes hands the documentation should be passed on to the new operator If the documentation gets misla...

Page 6: ...at all persons working with the Defensor PH28 PH28A are familiar and comply with the appropriate regulations on work safety and the prevention of accidents This unit may not be used by persons includi...

Page 7: ...r remove the mains plug by pulling the mains cable Make sure your hands are absolutely dry when pulling the plug out of the socket Lay out the mains cable so that it does not become a stumbling trap C...

Page 8: ...a coarse dust filter and a flock coated evaporator mat to operate the unit as a humidifier winter time operation 1 Air outlet grill 2 Radial fan 3 Rotary humidification drum 4 Evaporator mat 5 Base t...

Page 9: ...panel with display 9 Side cover 10 Type plate 11 Silver ionisation electrodes 12 Safety float 13 Level switch 14 Fuse 15 3 pole mains cable 16 Inlet valve 17 Water filter 18 Water supply connector PH2...

Page 10: ...ing The vaporizer mat is dipped into the base tub 4 and takes up water The air passing through the humidification drum absorbs the humidity The coarse dust filter retains dust particles up to 100 m If...

Page 11: ...e fan must be switched to the next highest level Operation as air purifier without humidification In this operating mode the fan is running continuously The humidification drum remains switched off Op...

Page 12: ...ent The ordered accessories with operating instructions according chapter 3 7 are packed separately 3 7 Accessories Defensor PH28 Defensor PH28A Filter set Winter optimized for air humidification Filt...

Page 13: ...tion Please preserve the original packing material in case you once have to return the unit for some reason In case you wish to dispose of the packaging observe the local regulations on waste disposal...

Page 14: ...of air is fully recirculated do not place the unit in recessed compart ments closed corridors behind curtains etc Do not place any objects on the unit performance reduction Continuous direct sunlight...

Page 15: ...has to be maintained The installation of a shut off valve next to the PH28A is mandatory Lay the connection hose carefully so that nobody will trip over it WARNING For the water installation the unit...

Page 16: ...ns CAUTION Make sure the required supply voltage see type plate matches the local mains voltage oth erwise do not connect the Defensor PH28 PH28A to the mains CAUTION The Defensor PH28 PH28A must be c...

Page 17: ...ank carriage removethetankcapandfillthetank with tap water using the supplied filling hose Do not use additives Relocate the tank cap Important Screw on tank cap until it comes to a stop CAUTION In or...

Page 18: ...ted every 5 seconds Operating mode B air humidification R Air purification without humidification K Combined mode purification humdification Fan step 1 2 3 4 or A1 A2 A3 A4 Act 38 rH BA3 Set 45 rH Act...

Page 19: ...ing mode Humidify Buzzer On Timer Adjust 5 3 Menu overview The following diagram shows the menu overview of the Defensor PH28 PH28A After switching on the unit is in the user level User level Timer le...

Page 20: ...ts we recommend a value of 40 45 rH Note After initial commissioning or replacement of the vaporizer mat the humidification perform ance of the Defensor PH28 PH28A will be slightly reduced be cause th...

Page 21: ...tting 1 Notes on setting The fan step to be selected depends on the operating mode and the size of the room The table below is meant to assist you in finding the optimum fan step Fan step max room vol...

Page 22: ...the operating mode see chapter 5 4 2 see chapter 5 4 4 modify confirm cancel Humidify Purify Combi mode Note The operating mode can be modified only if program mode is deactivated see chapter 5 5 Avai...

Page 23: ...mer Adjust 5 4 5 Calling timer level see chapter 5 4 4 see chapter 5 4 6 Calling timer level Leaving timer level For detailed information regarding the settings in the timer level see chapter 5 5 prog...

Page 24: ...e user level call the timer level see chapter 5 4 5 In the timer level you can activate and deactivate the program mode see chapter 5 5 2 you can set the day of the week and the hour see chapter 5 5 3...

Page 25: ...ting the current time see chapter 5 5 2 see chapter 5 5 4 modify confirm cancel Available settings Day of the week Mo Tu We Th Fr Sa Su Hour Format hh Minute Format mm Factory setting Notes on setting...

Page 26: ...ification R for purification without humidi fication and K for combined mode purification and humidification Fan step 0 1 2 3 4 Factory setting 45 rH BA0 Notes on setting After calling the modificatio...

Page 27: ...lock the keyboard press ESC key until approx 4 seconds the adjacentmessageappearsinthedisplay Thekeyboardislockednow Each time you press any key the adjacent message appears again To unlock the keyboa...

Page 28: ...for cleaning and replacing the individual components in the table below as approximate values If the room air is heavily contaminated the filters must be cleaned replaced more often If the water is ve...

Page 29: ...er on the floor and on the components of the unit 1 4 7 2 5 8 3 6 Press the snap and fold out the water tank cart Tip the swivel plate upwards Remove the air intake grills located on both sides of the...

Page 30: ...p with a lukewarm soap solution and rinse well with tap water Occasionally remove scale coating with a household decalcify agent observe safety notes in chapter 6 3 Finally rinse the screw cap well wi...

Page 31: ...place coarse dust filters Quattro filters together with the evaporator mat evaporator mat CAUTION Make sure the filters do not get wet Wet filters must be dry before reinstalling Water filter PH28A on...

Page 32: ...ands eyes and respiratory tracts therefore from contact with the agent and its vapour wear gloves goggles and work in a well ventilated room or outside CAUTION Do not use any solvents aromatised or ha...

Page 33: ...ther with the base tub into the unit Place the coarse dust filter with thebluesidefacingupwards fac ing to the centre when mounted or the Quattro filter with the fluffy side facing the bottom facing o...

Page 34: ...then displayed again Warning 6 Filter change Filter change ESC OK 6 6 Repair work Note Except for the change of the fuse and the replacement of damaged parts revealed upon main tenance the customer mu...

Page 35: ...cover and tighten both mounting screws 8 Insert and lock the water tank carriage see chapter 5 1 9 Reconnect the unit to the mains Replacing the ionizer electrodes 1 Shut down the Defensor PH28 and di...

Page 36: ...nnel Action To reset the message and to return to the standard operating display press the Enter or the ESC key 7 1 Event messages 7 2 Warning messages Display red LED Buzzer Error relay Resetting War...

Page 37: ...lose tank cap correctly PH28A check replace inlet valve Error 3 Filltime Error message is displayed until reset flashes buzzes activated Switch unit off then on again Note This message is displayed on...

Page 38: ...ot reach the set reference humidity value Evaporator mat not installed Install evaporator mat Room temperature too high Reduce room temperature to 20 22 C Unit very dirty Perform maintenance see chapt...

Page 39: ...er up The elimination of faults must be carried out only by qualified and well trained professionals Malfunctions relating to the electrical installation must only be repaired by authorized personnel...

Page 40: ...ly line PH28A only 2 Have the unit and all other system components if necessary unmounted by a qualified service technician 8 1 Taking out of service 8 2 Disposal Recycling At the end of the life span...

Page 41: ...ication capacity at 23 C and 45 rh 0 9 l h 1 2 l h 1 4 l h 1 6 l h For rooms up to a max of 430 m3 600 m3 730 m3 900 m3 Sound pressure level 40 dBA 48 dBA 54 dBA 58 dBA Sound power level according EN...

Page 42: ...control board T2 Transformer fan X5 Error contact max 250 VAC X9 Programming interface Y1 Inlet valve PH28A only Y2 Inlet safety valve PH28A only PH28 X14 X15 X17 5V 4 3 2 1 U1 P1 T1 B3 B1 B2 X5 F1 T...

Page 43: ...43 10 2 Spare parts list PH28 1 6 5 3 7 10 11 12 13 20 27 31 37 9 8 2 4 36 33 32 34 35 38 19 17 18 14 15 54 24 22 23 21 56 52 51 25 18 53 50 16 28 29 30 26 55...

Page 44: ...pcs RAL or NCS code according type plate 21 2560889 Handle 22 1102394 Door locking set 23 2560883 Stop lever cpl left 24 2560884 Stop lever cpl right 25 1103732 Door arresting set 26 2560917 Hinged p...

Page 45: ...45 10 3 Spare parts list PH28A 1 6 60 62 61 63 5 3 7 10 11 12 13 20 27 31 8 2 4 36 33 32 34 35 38 19 17 18 14 15 24 22 23 21 65 25 16 28 29 30 26 64 37 9...

Page 46: ...lor 2 pcs RAL or NCS code according type plate 21 2560889 Handle 22 1102394 Door locking set 23 2560883 Stop lever cpl left 24 2560884 Stop lever cpl right 25 1103732 Door arresting set 26 2560917 Hin...

Page 47: ...Walter Meier Climate International Ltd 2011 Printed in Switzerland Technical modifications reserved...

Page 48: ...er Climate International Ltd Talstr 35 37 P O Box CH 8808 Pf ffikon Switzerland Phone 41 55 416 61 11 Fax 41 55 416 62 62 www waltermeier com international climate waltermeier com Consulting Sales and...

Reviews: