33
6.4
Reassembly of the unit
CAUTION!
Before reassembling the Defensor PH28 check all components for possible damage. Do not reuse
damaged parts but replace them before reassembling the unit
Reassemble the unit as follows:
1
4
2
5
3
6
Install the vaporizer mat and the
retaining mesh in the humidifica
-
tion drum.
Slide the humidification drum (with
the internal geared wheel facing
backwards) together with the base
tub into the unit.
Place the
coarse dust filter with
the blue side facing upwards
(fac
-
ing to the centre when mounted)
or
the Quattro filter with the fluffy
side facing the bottom
(facing
outwards when mounted) in the
air intake grills, then mount the
retainer frame.
Mount the air intake grill, then tip
the swivel plate down.
Slide the water tank cart into the
unit.
Press the lock mechanism of the
handle on both sides of the cart (the
handle slides down), then tip up the
cart until the lock engages.
Important!
After reinstalling the
water tank wait by the unit until the
filling sound stops.
2.
3.
1.