EN
11
defa.com
1 =
8 A
Fixing screw
Cable entry
Rotary switch
10. Set the maximum current rating for the charging station by turning the rotary switch to the
correct position. Follow the table next to the rotary switch on the charging unit or in the
image below.
11.
Insert the conductors L, N and PE (earth) into the terminal block (see image below), and
check that they are all firmly attached.
i
NOTICE
If the PE conductor is not isolated, add an insulation tube or electrical tape in
the exposed area.
12. Place the cable in the position shown in the image below.