Page 1: ...IM Inst RF360en v0 4 ENGLISH INSTALLATION Manual RF 360 ...

Page 2: ...r use is allowed and does not require prior approval The declaration of conformity is available on request at support dedrone com Copyright This manual is the intellectual property of Dedrone GmbH and is protected by copyright All rights reserved Dedrone GmbH Miramstraße 87 34123 Kassel Germany Fon 49 561 861799 0 Fax 49 561 861799 111 Email info dedrone com 2019 Dedrone GmbH All rights reserved D...

Page 3: ... 8 5 3 Mounting Location 9 5 4 Overvoltage Protection 10 6 Installation 10 6 1 Power Supply 10 6 2 Cable Requirements 11 6 3 Cable Preparation for LAN connection 11 6 4 Install the Sensor 12 7 Integrate the RF 360 in your DroneTracker 15 7 1 Integrate the RF 360 in your on prem DroneTracker Server 15 7 2 Integrate the RF 360 via Dedrone Cloud 17 8 Cleaning 18 9 Decommissioning 18 9 1 Shut down the...

Page 4: ...mentation is an integral part of this product Keep the documentati on in a convenient place for future reference and observe all instructions contained therein The type label must remain permanently attached to the product Compliance Information Statement FCC and IC The RF Sensor RF 360 complies with Industry Canada license exempt RSS standard s and complies with Part 15 of the FCC Rules Operation...

Page 5: ... the device and your body 1 3 Safety Information Read follow and retain all of the following safety instructions Heed all warnings on the unit and in the operating instructions before operation Warning Setup should be carried out by trained personnel only in accordance with the national electric code ANSI NSPA and all local country codes Danger of life due to electric shock Whenever any damage to ...

Page 6: ...e DroneTracker System B C A D It scans a wide frequency band for radio frequencies and classifies them The data is recorded and available on the user interface DroneTracker UI 3 Unpacking This equipment should be unpacked and handled with care Check the exterior of the packaging for visible damage If an item appears to have been damaged in shipment notify the shipper immedia tely Despite careful c...

Page 7: ...cluded If any items are missing notify your Dedrone Partner Do not use this product if any component appears to be damaged Please contact Dedrone in the event of damaged goods 5 Select the Mounting Place The position of the RF 360 has strong impact to the detection and direction finding range and ac curancy The RF 360 is intended for an installation on top of a pole Make sure that a suitable pole ...

Page 8: ...ead power lines power circuits or electrical lights Electrical discharge can damage the device Select a secure installation location and mounting position for the device Ideally this is a location where the device cannot be interfered with either intentionally or accidentally 5 2 Direction Finding and Localization Conditions For accurate localization results follow the guidance below in addition t...

Page 9: ... 1 300 ft 100 m to 400 m For the best result Dedrone strongly recommends a distance of 1 000 ft to 1 300 ft 300 m to 400 m Choose the postion depending on your monitoring focus Increase the distance between the sensors to increase the accuracy at further distances Localization accuracy increases as the drone gets closer to the sensors 5 3 Mounting Location Mounting Surface Make sure the selected m...

Page 10: ...360 Ensure that the location has the appropriate clearance from power and lightning conductors in accordance with NEC725 and NEC800 CEC Rule 16 224 and CEC Section 60 and Section 810 of the National Electrical Code ANSI NFPA No 70 6 Installation 6 1 Power Supply The RF 360 can use two kinds of power supplies AC power supply with the supplied power plug via a socket AC 100 240V 50 60 Hz Make sure t...

Page 11: ...ements 6 3 Cable Preparation for LAN connection For a weather resistant connection to the RF 360 it is necessary to put on the supplied outdoor housing to the prewired RJ45 cordset Procedure 1 Put the gland nut onto the cable Thereby make sure that the thread shows to the plug 2 Open the sleeve and close it around the cable Thereby make sure that the closer ring shows to the gland Put the sealing ...

Page 12: ...1 Open the carton remove the upper foam 2 Open the cover Stuck the supplied tool in the slot bet ween the cover screws Gently pry the cover on both sides The cover comes up a little bit 3 Remove the cover and put it aside 4 Loosen both fixing screws and the security screw You do not need to unscrew the screws completely 5 Take out the pole mount 6 Put the pole mount on the pole To open up the pole...

Page 13: ...equired screw down the supplied fall protection ring and connect your suitable fall protection to the ring The fall protection must be dimensioned according to installation height in terms of thickness and length 10 Place the RF 360 on the pole mount Slide the fixing screws in the screw guides of the mounting plate 1 Thereby make sure that the two flaps of the pole mount slides in the slot of the ...

Page 14: ...e sure that PoE 802 3at is enabled on the connected switch If the patch cable is connected to the net work and PoE is activated the RF 360 boots automatically and after approxi mately 1 second the blue button at the RF 360 illuminates indicating that the hardware is ready The patch cable is connected to the net work with activated PoE and the RF 360 does not boot automatically after appro ximately...

Page 15: ... directly If the RF 360 and the DroneTracker Server are in different networks refer to the Dedrone Planning Manual or consult your network administrator 12 To operate the RF 360 via the supplied AC cable connect the AC cable to the AC socket Remove the protective cap from the AC plug Plug the AC cable into the plug 1 The plug clicks into place and the arrow on the plug points to the lock symbol on...

Page 16: ...er drag and drop the element to the desired position 7 Choose Save changes The window Site Configuration disappears 8 Choose OPTIONS Map Editor and choose the RF 360 9 An accurate alignment of the sensor and configuration in the DroneTracker are prerequisites for a good direction finding result If the sensor was aligned via a prominent landmark drag and drop the sensor symbol to the installed posi...

Page 17: ... Site Configuration 4 Choose Add Register device The window Register device appears 5 Enter the registration key of your sensor and choose OK The RF 360 appears in the Site Explorer 6 To sort the RF 360 in the Site Explorer drag and drop the element to the desired position 7 Choose Save changes The window Site Configuration disappears 8 Choose OPTIONS Map Editor and choose the RF 360 9 An accurate...

Page 18: ...0 in the grip recess The RF 360 shuts down and the blue light goes out Shut down directly at the RF 360 9 2 Dismantling 9 3 Disposal Hot surface due to permanent sunlight The surface of the RF 360 may become hot from permanent strong sunlight Wear safety gloves when dismantling the device Dispose the RF 360 at the end of its service life in accordance with the disposal regulations for electronic w...

Page 19: ...rotection Rating IP65 Operating Temperature 4 F to 131 F 20 C to 55 C Power Supply AC 100 240V 50 60 Hz max 1 A or PoE IEEE 802 3at 25 W Connectivity Via LAN to existing IT infrastructure or via the integrated mobile connection in the Dedrone Cloud Configuration Operation and Alarms Via DroneTracker software software version 4 1 and valid license Software Updates Firmware and DroneDNA updates via ...