Select the Mounting Place
Dedrone
8
v12.0 IM-Inst-RF300en
Note the properties of each RF-300
. This is needed for the correct configuration and
for service.
We recommend the table below. The following information is important:
•
Serial Number
•
GPS position (longitude and latitude)
•
Horizontal angle
Serial number
(see prouct plate)
GPS position
(in degree, e.g. 52.516295, 13.377653)
Horizontal angle (azimuth)
in degrees (0 = north, 90 = east, 180 = south,
270 = west)
longitude:
latitude:
longitude:
latitude:
longitude:
latitude:
5.1.2 Direction Finding and Localization Conditions
For accurate localization results, follow the guidance below in addition to the Detection Conditions
(see 5.1.1 Detection Conditions, page 7).
The position is determined by the intersection of at least two bearings. Therefore minimum two
RF-300 sensors are required for localization, but we recommend at least three RF-300 sensors as
this significantly reduces localization errors.
For best localization results, all RF-300 sensor should be installed at the same height.
Do not install the device nearby the following objects:
•
Metal surfaces or vaporized glass
Disturbs the detection and prevents the localization
•
Walls
These share the detection area and prevent classification of signals behind the wall
•
Base station and other strong signale sources
The detected signals are getting interfered
•
Any excessive heat sources
•
Any overhead power lines, power circuits, or electrical lights
electrical discharge can damage the device.
Select a secure installation location and mounting position for the device. Ideally, this is a location
where the device cannot be interfered with, either intentionally or accidentally.