Distances between the RF-300s
The distance between the RF-300 usually should be 330 ft to 1,300 ft (100 m to 400 m).
330 ft to 1,300 ft
(100 m to 400 m)
330 ft to 1,300 ft
(100 m to 400 m)
Distance between the RF-300s
Lightning Protection Installation with RF-300s
For the best result, Dedrone strongly recommends a distance of
1,000 ft to 1,300 ft (300 m to
400 m)
.
Choose the postion depending on your monitoring focus. Increase the distance between the
sensors to increase the accuracy at further distances.
Localization accuracy increases as the drone gets closer to the sensors.
5.2 Overvoltage Protection
For safe mounting in an exposed position overvoltage protection must be observed.
Ensure that the pole is connected to the lightning conductor of the building. The RF-300 itself
must not be grounded directly. The lightning conductor must be installed at least 1.5 m above the
RF-300.
330 ft to 1,300 ft
(100 m to 400 m)
Ensure that the location has the appropriate clearance from power and lightning conductors, in
accordance with NEC725 and NEC800 (CEC Rule 16-224 and CEC Section 60).