Hardware description |
Seite
15
2.2.5. Outputs
2.2.5.1. Relay outputs
The relays are able to switch voltages up to 36V. The max. current is 1A at a
max. power of 15W.
Additionally, the relays provide a safe electrical isolation of the module to the
connected equipment.
2.2.5.2. Timeout protection
The timeout-protection gives the possibility to switch-off automatically the
outputs to prevent damage. This takes place, if in a predefined time frame any
communication with the module was possible. Reasons could be cable
disruption, PC-crash and so on. This way damage control, surcharge of
connected equipment and risk of accidents can be avoided.
2.2.5.3. Visual control of the outputs (depends of module)
The state of each output is directly signalized by a separate LED. This simplifies
to detect and rectify wiring errors, because the signals on the cables are directly
observable.
Summary of Contents for ETH-RELAIS-8
Page 1: ...Hardware Description Juli ETH RELAIS 8 OPTOIN 8 2019 ...
Page 6: ...I Introduction Seite 6 Introduction ...
Page 8: ...II Hardware description Seite 8 Hardware description ...
Page 13: ...Hardware description Seite 13 2 2 3 Overview screen ...
Page 17: ...Hardware description Seite 17 2 3 2 Product pictures ETH RELAIS 8 ...
Page 18: ...Hardware description Seite 18 2 3 3 Overview screen ...
Page 21: ...Hardware description Seite 21 ...
Page 22: ...III Hardware Seite 22 Hardware ...
Page 28: ...Hardware Seite 28 Geben Sie hier den Text ein ...
Page 29: ...IV Firmware update Seite 29 Firmware update ...
Page 32: ...Firmware update Seite 32 After successful update procedure the message FLASH OK appears ...
Page 33: ...V Software Seite 33 Software ...
Page 56: ...Software Seite 56 Choose the option create VIs for DLL and press continue ...
Page 71: ...Software Seite 71 compile_delib_cli_usb sh with which you can compile the project under Linux ...
Page 77: ...VI DELIB API reference Seite 77 DELIB API reference ...
Page 107: ...VII Appendix Seite 107 Appendix ...