![DeDietrich Vivadens MCR-P 24 User Manual Download Page 22](http://html1.mh-extra.com/html/dedietrich/vivadens-mcr-p-24/vivadens-mcr-p-24_user-manual_2462498022.webp)
5.6
Reading out measured values
The following values can be displayed in the information menu
Q
:
4
t1
=
Flow temperature (°C)
4
t2
=
Return temperature (°C)
4
t3
=
DHW sensor temperature (°C)
This temperature is used only for internal management in DHW
mode. During DHW draw-off, this value does not correspond to
the actual DHW outlet temperature (it is always lower).
4
t4
=
Outside temperature (°C)
4
fl
=
Ionization current (μA)
4
Mf
=
Fan speed (rpm)
1. Press the
f
key. The symbol
Q
flashes.
2. To access the parameters, press key
S
.
3. Press the
[+]
key successively to scroll down the various
parameters.
4. Press the
>
key 2 times to return to the current operating mode
T000138-A
5. Operation
MCR-P 24/28 BIC PLUS
21
170915 - 127686-04