5.5.5.
Stopping domestic hot water production
1. Press the
N
key.
The symbol
N
and the current temperature are displayed.
2. Press the key
[-]
several times until the value
0ff
is displayed.
3. To confirm the new value, press the key
S
.
The symbol
T
appears.
It also possible to modify this setting using the parameter
p3
.
¼
See chapter: "Other settings", page 19.
5.5.6.
Other settings
Parameter Description
Adjustment range
Factory setting
p1
Flow temperature
20 to 85 °C
75 °C
p2
Domestic hot water temperature 40 to 65 °C
60 °C
p3
Heating / DHW mode
0 = Heating deactivated (
C
) / DHW deactivated (
T
)
1
1 = Heating activated (
D
) / DHW activated (
N
)
2 = Heating activated (
D
) / DHW deactivated (
T
)
3 = Heating deactivated (
C
) / DHW activated (
N
)
p4
ECO mode
0 = Comfort mode
0
1 = Energy-saving mode
2 = Management using a programmable thermostat
p5
Anticipation resistance
0 = No anticipation resistance for the ON/OFF thermostat
0
1 = Anticipation resistance for the ON/OFF thermostat
p6
Display screen
0 = The screen stays off
2
1 = The screen stays on
2 = The screen switches off automatically after 3 minutes
GA
,
Ajj
T000142-A
5. Operation
MCR-P 24/28 BIC PLUS
19
170915 - 127686-04
Summary of Contents for Vivadens MCR-P 24
Page 1: ...Vivadens EN Wall hung gas condensing boilers MCR P 24 28 BIC PLUS User Guide 127686 04...
Page 4: ...3 170915 127686 04...
Page 40: ...11 Appendix MCR P 24 28 BIC PLUS 39 170915 127686 04...
Page 41: ...MCR P 24 28 BIC PLUS 11 Appendix 170915 127686 04 40...
Page 42: ......
Page 43: ......