background image

4.4

Hydraulic installation diagram

9

Stop valve

28

Domestic cold water inlet

29

Pressure reducer

30

Safety unit

57

Domestic hot water outlet

a

Cold water inlet with an integrated non-return valve

b

Connection to the DHW calorifer cold water inlet

c

Stop cock

d

safety unit 7 bar

e

Drain opening

4.5

Hydraulic connections

4.5.1.

Hydraulic connection of the primary circuit
(exchanger circuit)

n

DHW tank combined with a MCA - MCR boiler

Use the EA137 connecting kit to connect the DHW tank to the boiler

MCA

.

Use the HG30 connecting kit to connect the DHW tank to the boiler

MCR

.

8953N155-C

30

29

28

57

9

C000711-F

a

b

c

d

(54)

2 cm

e

28

9

30

29

SR130

4. Installation

26/03/2014 - 300009755-001-03

12

Summary of Contents for SR 130

Page 1: ...EN Domestic hot water tank SR130 Installation User and Service Manual 300009755 001 03 ...

Page 2: ...1 General description 8 3 2 Technical specifications 9 3 2 1 Characteristics of the DHW calorifier 9 3 2 2 Specifications of the DHW sensor 9 4 Installation 10 4 1 Regulations governing installation 10 4 2 Package list 10 4 3 Choice of the location 10 4 3 1 Type plate 10 4 3 2 Positioning of the appliance 11 4 3 3 Main dimensions 11 4 4 Hydraulic installation diagram 12 4 5 Hydraulic connections 1...

Page 3: ...0 5 Commissioning 22 5 1 Putting the appliance into operation 22 6 Checking and maintenance 23 6 1 General instructions 23 6 2 Sacrificial anode 23 6 2 1 Checking the magnesium anode 23 6 2 2 Replacing the magnesium anode and descaling 24 6 3 Safety valve or safety unit 24 6 4 Cleaning the casing material 25 6 5 Maintenance form 26 7 Spare parts 27 7 1 General 27 7 2 Spare parts 28 8 Warranty 29 8...

Page 4: ...3 26 03 2014 300009755 001 03 ...

Page 5: ...of a dangerous situation causing slight physical injury CAUTION Risk of material damage Signals important information Signals a referral to other instructions or other pages in the instructions 1 2 Abbreviations 4 CFC Chlorofluorocarbon 4 DHW Domestic hot water 1 3 Liabilities 1 3 1 Manufacturer s liability Our products are manufactured in compliance with the requirements of the various applicable...

Page 6: ...ntain it in good working order 4 Give all the instruction manuals to the user 1 3 3 User s liability To guarantee optimum operation of the appliance the user must respect the following instructions 4 Read and follow the instructions given in the manuals provided with the appliance 4 Call on qualified professionals to carry out installation and initial start up 4 Get your installer to explain your ...

Page 7: ...agnetic Compatibility Directive Reference Standards EN 50 081 1 EN 50 082 1 EN 55 014 1 4 2 Directive 97 23 EC This product conforms to the requirements of european directive 97 23 EC article 3 paragraph 3 on pressure equipment 1 4 3 Factory test Before leaving the factory each appliance is tested for the following 4 Water tightness 4 Air tightness 4 Electrical safety SR130 1 Introduction 26 03 20...

Page 8: ...ter must not circulate via the exchanger 4 To take advantage of the guarantee no modifications must be made to the appliance 4 To reduce heat losses as much as possible insulate the pipes Casing components Only remove the casing for maintenance and repair operations Put the casing back in place after maintenance and repair operations Instructions stickers The instructions and warnings affixed to t...

Page 9: ... which protects the tank from corrosion 4 The heat exchanger welded into the tank is made of smooth tubing the external surface of which which is in contact with domestic water is enamelled 4 The appliance is highly insulated with CFC free polyurethane foam which reduces thermal losses to a minimum The insulating material can be easily detached from the tank This measure facilitates the recycling ...

Page 10: ...SR130 Performances related to the boiler type MCA15 MCA25 MCR24 EMC M 24 PMC M 24 MS24 MSL24FF MSL31FF Power exchanged 1 kW 14 5 24 22 6 22 5 24 25 31 Flow per hour T 35 C 1 l h 355 590 555 560 590 1430 1770 Specific flow T 30 C 10 minutes 2 l min 20 20 16 5 20 20 11 5 13 7 Draw off capacity l 10 mm 200 200 165 200 200 115 137 1 Domestic cold water inlet 10 C Domestic hot water outlet 45 C Primary...

Page 11: ...MCA boiler To be ordered separately 4 Package AD226 sensor for MCR EMC PMC boiler 4 Package AD250 sensor for MS boiler 4 Package HX52 sensor for MSL boiler 4 Package EA137 Hydraulic connection kit for MCA boiler 4 Package HG30 Hydraulic connection kit for MCR boiler 4 Package HX32 Hydraulic connection kit for MS boiler 4 Package HR92 Hydraulic connection kit for EMC PMC boiler 4 Package HX32 HX18 ...

Page 12: ...Main dimensions A Primary inlet G 3 4 B Primary outlet G 3 4 C Domestic hot water outlet R 3 4 Red marking D Domestic cold water inlet R 3 4 Blue marking E Magnesium anode F Sensor tube G Distance to be observed between tank and boiler MCA 250 mm MCR 446 mm MS24 MSL 446 mm EMC PMC 446 mm 1 Tank 2 Boiler 1 wall R Conical threading G Exterior cylindrical threading sealed by sheet gasket 8953N150C 1 ...

Page 13: ...let c Stop cock d safety unit 7 bar e Drain opening 4 5 Hydraulic connections 4 5 1 Hydraulic connection of the primary circuit exchanger circuit n DHW tank combined with a MCA MCR boiler Use the EA137 connecting kit to connect the DHW tank to the boiler MCA Use the HG30 connecting kit to connect the DHW tank to the boiler MCR 8953N155 C 30 29 28 57 9 C000711 F a b c d 54 2 cm e 28 9 30 29 SR130 4...

Page 14: ... HX32 connecting kit to connect the DHW tank to the boiler 1 Primary inlet 2 Domestic hot water outlet 3 Domestic cold water inlet 4 Primary outlet CAUTION Connect the hoses taking care to interpose the gaskets n DHW tank combined with a EMC PMC boiler Use the HR92 connecting kit to connect the DHW tank to the boiler EMC PMC C000704 D C003394 C 4 Installation SR130 13 26 03 2014 300009755 001 03 ...

Page 15: ...rame 5 Fill the calorifier slowly through the disconnector 6 Close the manual air vent when water is coming out 7 Open the return tap of the mounting frame Refer to the installation and maintenance instructions of the boiler CAUTION Connect the hoses taking care to interpose the gaskets n DHW tank combined with a MSL boiler Use the HX32 connecting kit to connect the DHW tank to the boiler 1 Primar...

Page 16: ...ontrol units All countries except Germany 7 bar safety valve 0 7 MPa Germany 10 bar safety valve 1 0 MPa maximum 4 Integrate the safety valve in the cold water circuit 4 Install the safety valve close to the calorifer in a place which is easy to access n Size 4 The diameter of the safety unit and its connection to the calorifer must be at least equal to the diameter of the domestic cold water inle...

Page 17: ...is greater than the admissible operating pressure CAUTION If the mains pipes are made of copper fit a sleeve made of steel cast iron or any other insulating material between the tank s hot water outlet and the pipes to prevent corrosion to the connection n Connecting the domestic cold water Make the connection to the cold water supply according to the hydraulic installation diagram Refer to the in...

Page 18: ...taps are turned on a circulation loop between the draw off points and the recirculation pipes in the DHW calorifer can be installed A non return valve must be included in this loop Run the domestic hot water circulation loop via the boiler control system or an additional timer program to optimse energy consumption n Measures to take to prevent hot water flow return Fit a one way valve to the domes...

Page 19: ...ater sensor to the corresponding terminal on the control panel 4 6 2 DHW tank combined with a MCR boiler WARNING Only qualified professionals may carry out electrical connections always with the power off C002859 B 2 1 S SYST TA S ECS S EXT S DEP C 2 1 2 1 2 1 2 1 2 1 S DEP B 2 1 4 3 SR130 4 Installation 26 03 2014 300009755 001 03 18 ...

Page 20: ...minal on the control panel 4 6 3 DHW tank combined with a MS boiler WARNING Only qualified professionals may carry out electrical connections always with the power off 1 Access the boiler s terminal block Refer to the installation and maintenance instructions of the boiler C000700 B OPEN TERMINAL BLOCK 1 2 C003395 A 3 4 Installation SR130 19 26 03 2014 300009755 001 03 ...

Page 21: ... off 1 2 6 5 1 1 2 3 4 5 C004761 A 1 Access the boiler s terminal block Refer to the installation and maintenance instructions of the boiler 2 Connect the domestic hot water sensor to the corresponding terminal on the control panel 4 6 5 DHW tank combined with a EMC PMC boiler WARNING Only qualified professionals may carry out electrical connections always with the power off SR130 4 Installation 2...

Page 22: ...llation and maintenance instructions of the boiler 2 Connect the domestic hot water sensor to the corresponding terminal on the control panel C004046 B 1 2 3 4 5 BL 6 8 7 10 9 11 13 11 3 4 Tout Tdhw BL 12 4 Installation SR130 21 26 03 2014 300009755 001 03 ...

Page 23: ...ating steps 2 to 4 for each hot water tap Carefully degas the DHW tank and the distribution network in order to eliminate noises and hammering caused by trapped air moving in the pipes during draw off 6 Vent the tank exchanger circuit using the bleed valve provided for this purpose 7 Check the safety devices particularly the valve or safety unit referring to the instructions provided with these co...

Page 24: ...ing the magnesium anode Carry out a visual check of the anode 4 The anode must be replaced if its diameter is less than 15 mm 4 The magnesium anode must be checked at least every 2 years After the first check determine the frequency of future checks on the basis of anode wear If the anode must be replaced proceed as described below 6 Checking and maintenance SR130 23 26 03 2014 300009755 001 03 ...

Page 25: ...ion of the DHW calorifier 10 Replace the E lip gasket F retainer ring Place the positioning lug on the gasket toward the outside of the tank CAUTION Each time it is opened the lip gasket retainer ring unit must be replaced to guarantee tightness 11 Then replace all the parts in reverse order CAUTION The screws retaining the visit trap must be tightened to 6 N m 1 0 Use a torque wrench Approximatel...

Page 26: ...6 4 Cleaning the casing material Clean the outside of appliances using a damp cloth and a mild detergent 6 Checking and maintenance SR130 25 26 03 2014 300009755 001 03 ...

Page 27: ...ance form No _____ Date _________ Checks made ______________________________ Remarks _____________________ By _______________ Signature ____________ SR130 6 Checking and maintenance 26 03 2014 300009755 001 03 26 ...

Page 28: ...tion or maintenance work that a component in the appliance needs to be replaced use only original spare parts or recommended spare parts and equipment To order a spare part give the reference number shown on the list 7 Spare parts SR130 27 26 03 2014 300009755 001 03 ...

Page 29: ... 8375 4945 Earth wire 3 8953 5528 Complete cover 4 89705511 Seal kit 7 mm retainer ring 6 8953 8593 Top cover 7 9536 2445 NTC DHW sensor 5 m 8 8199 4919 2 PIN DHW probe connector 10 8953 5529 Accessories bag 6 2 4 3 8953N148C SR130 7 Spare parts 26 03 2014 300009755 001 03 28 ...

Page 30: ...8 April amended by Decree Law 84 2008 of 21 May warranties relating to sales of consumer goods and other implementing rules Other countries The following provisions are not exclusive of the buyer being able benefit from the legal provisions applicable regarding hidden defects in the buyer s country Starting from the purchase date shown on the original installer s invoice your appliance has a contr...

Page 31: ...ear negligence repairs by unqualified parties faulty or insufficient monitoring and maintenance faulty power supply or the use of unsuitable fuel Sub assemblies such as motors pumps electric valves etc are guaranteed only if they have never been dismantled The legislation laid down by european directive 99 44 EEC transposed by legislative decree No 24 of 2 February 2002 published in O J No 57 of 8...

Page 32: ...etrich cz IT DE DIETRICH THERMIQUE S A S DE DIETRICH THERMIQUE Iberia S L U www dedietrich calefaccion es C Salvador Espriu 11 08908 L HOSPITALET de LLOBREGAT 34 935 475 850 info dedietrich calefaccion es ES 129164 Россия г Москва Зубарев переулок д 15 1 Бизнес центр Чайка Плаза офис 309 7 495 221 31 51 CZ Copyright All technical and technological information contained in these technical instructi...

Reviews: