20181270 CR v8-2019Page 31
- Once you have checked that the wall is solid and able to bear the weight of the indoor unit, you can begin to drill
holes in the wall.
- Secure the support to the wall using suitable cross-headed screwdrivers.
- Use a spirit level to ensure that the support is horizontal. If it is not level, condensate could leak from the air-
conditioner when it operates in cooling mode.
- Attach the indoor unit to the support using the upper tabs. Ensure that the indoor unit is properly
centred.
- Place the indoor unit on the mounting plate and push it until the hooks are firmly fixed in the guides
and you hear them "click".
Condensate
discharge pipe
Refrigerant
connection
Adhesive tape