2. Press the
)
key 3 times. The
Co un 4
menu is displayed.
3. Press the
MODE
B
key to go to the Counters menu. The number
of the counter is shown to the right of the display.
4. Use the
(
and
)
keys to switch from one counter to another (See
table below).
5. To exit this menu, press the
MODE
B
key.
6. To go back to the main display, press the
MENU
button.
Meter Description
Unit
1
Total electric energy input for DHW production
kWh
2
Electric energy input by the compressor in the last 24 hours
The counter is reset at 00:00 hours every day
Wh
3
Electric energy input by the electrical back-up in the last 24 hours
The counter is reset at 00:00 hours every day
Wh
4
Number of hours operation of the hydraulic backup
h
5
Number of hours powered up
h
6
Instantaneous output
W
n
Resetting the counters
1. Press once the
MENU
key. The
SE nS 1
menu is displayed.
2. Press the
)
key 3 times. The
Co un 4
menu is displayed.
3. Press the
MODE
B
key to go to the Counters menu. The number
of the counter is shown to the right of the display.
4. Use the
(
and
)
keys to switch from one counter to another.
5. Press the
V
key to reset the meter displayed to zero.
C004186-A
1
4
3
4
1
2
MENU
MODE
C003210-C
1
1
4
3
4
1
2
MENU
MODE
C004186-A
1
4
3
4
1
2
MENU
MODE
C003210-C
1
1
4
3
4
1
2
MENU
MODE
TWH 200E TWH 300E TWH 300EH
6. Commissioning
19/01/2015 - 300026515-001-05
51