n
Pipe length
CAUTION
Do not use accessories that may cause considerable
pressure drops (extraction grid with mosquito screen,
partially extended flexible duct, etc.). If the pressure drops
are greater, the performance of the appliance will be
impaired and the loading times increased.
Maximum length of the air connection m
diameter 160 mm
26
Accessories
package Equivalent length in m
Galvanised 90° elbow (Diameter 160 mm)
EH77
1.0
Adapter sleeve (Diameter 160 mm)
EH205
1.5
Insulated flexible duct (Diameter 160 mm - Length 3 m)
EH206
3.0
Passing through walls (Diameter 160 mm) + Closing plate
EH208
7.0
Outside grid (Diameter 160 mm) (aluminium)
EH209
8.0
PPE duct (Diameter 160 mm - Length 2x1 m) + 2 sleeves
EH272
0.2
290° elbows (PPE) (Diameter 160 mm) + 2 sleeves
EH273
0.2
Roof outlet Black (Diameter 160 mm)
EH275
2.0
Reduced elbow kit
EH434
6.0
Outside grate for taking in and discharging air (Diameter 160 mm) EH558
1.0
TWH 200E TWH 300E TWH 300EH
5. Installation
19/01/2015 - 300026515-001-05
25