2 / INSTALLING YOUR APPLIANCE
EN
= =
ASSEMBLING THE VENTILATION
SHAFT
•
Outdoor evacuation
— Using the two screws (fig. 1), attach the metal
ventilation shaft bracket against the wall, flush
with the ceiling for support.
— Mount the back-flow valve near the motor
outlet (fig. 2). This back-flow valve makes it
possible to block the entry of air from the
outside.
— If a 125-mm flue is being installed, use the
adapter provided (fig. 3).
If the diameter of your exterior flue is less than
125 mm, you must connect your hood in the
recycling configuration.
— Slide the end of the flue over the motor outlet
(fig. 4).
— Prepare your telescoping ventilation shaft,
taking care not to block the vents (fig. 4).
Fit the ventilation shafts into one another as far
as they will go.
— Attach the upper portion of the ventilation
shaft (B/fig. 4 on the metal ventilation shaft
bracket (A/fig. 4) using the two screws (G/fig. 4).
— Adjust the length of the telescoping ventilation
shaft by bringing down the lower part and fitting
it into the top of the hood.
•
fig. 1
fig. 4
fig. 2
fig. 3
A
B
C
D
E
Ventilation shaft bracket
Flue
Adaptor
Back-flow valve
Motor outlet
F
Telescoping ventilation shaft
Ventilation shaft holding screw