Code Faults
Cause
of the
fault
Description
Checking / solution
D11
D12
D13
ROOM S.A FAIL.
ROOM S.B FAIL.
ROOM S.C FAIL.
SCU
A room temperature sensor fault
B room temperature sensor fault
C room temperature sensor fault
Note:
The circuit concerned operates without any
influence from the room sensor.
Bad connection
Sensor fault
4
Contact the professional who takes
care of maintenance of the appliance
D14
MC COM.FAIL
SCU
Break in communication between the SCU
PCB and the radio module
Bad connection
4
Check the link and the connectors
Boiler module failure
4
Change the boiler module
D15
ST.TANK S.FAIL
SCU
Storage tank sensor fault
Note:
The hot water storage tank reheating
operation is no longer assured.
Bad connection
Sensor fault
4
Contact the professional who takes
care of maintenance of the appliance
D16
D16
SWIM.P.B. S.FAIL
SWIM.P.C. S.FAIL
SCU
Swimming pool sensor fault circuit B
Swimming pool sensor fault circuit C
Note:
Swimming pool reheating is always done
during the circuit's comfort period.
Bad connection
Sensor fault
4
Contact the professional who takes
care of maintenance of the appliance
D17
DHW 2 S.FAIL
SCU
Sensor fault tank 2
Bad connection
Sensor fault
4
Contact the professional who takes
care of maintenance of the appliance
D18
ST.TANK S.FAIL
SCU
Solar tank sensor fault
Bad connection
Sensor fault
4
Contact the professional who takes
care of maintenance of the appliance
D19
SOL.COL.S.FAIL
SCU
Header sensor fault
Bad connection
Sensor fault
4
Contact the professional who takes
care of maintenance of the appliance
D20
SOL COM.FAIL
SCU
Interruption in communication between the SCU PCB and the solar control system
4
Contact the professional who takes care of maintenance of the appliance
D27
PCU COM. FAIL
SCU
Communication failure between the SCU and PCU PCBs
4
Contact the professional who takes care of maintenance of the appliance
D32
5 RESET:ON/OFF
SCU
5 resets done in less than an hour
4
Switch off heat pump and start up again
D37
TA-S SHORT-CIR
SCU
The Titan Active System® is short-circuited
4
Check that the connection cable between the SCU PCB and the anode is not short-
circuited
4
Check that the anode is not short-circuited
Remarks:
Domestic hot water production has stopped but can nonetheless be restarted using key
r
.
The tank is no longer protected.
If a tank without Titan Active System® is connected to the heat pump, check that the
TAS simulation connector (delivered in package AD212) is fitted to the sensor board.
AWHP MIT-IN iSystem
5. Troubleshooting
06/09/2012 - 300027618-001-01
26