Product name
Symbol
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
Annual energy consumption under average conditions
Q
HE
kWh
2353
2124
3499
Annual energy consumption under colder conditions
Q
HE
kWh
4483
3721
4621
Annual energy consumption under warmer conditions
Q
HE
kWh
1249
1492
1904
Rated air flow rate, outdoors for air-to-water heat pumps -
m
3
/h
2680
2700
3300
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
Tab.11 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
Symbol
Unit
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Air-to-water heat pump
Yes
Yes
Water-to-water heat pump
No
No
Brine-to-water heat pump
No
No
Low-temperature heat pump
No
No
Equipped with a supplementary heater
Yes
Yes
Heat pump combination heater
No
No
Rated heat output under average conditions
Prated
kW
6
9
Rated heat output under colder conditions
Prated
kW
4
7
Rated heat output under warmer conditions
Prated
kW
8
13
Declared capacity for heating for part load at an indoor temperature of
20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW
6.8
8.6
T
j
= +2 °C
Pdh
kW
5.3
6.5
T
j
= +7 °C
Pdh
kW
9.0
12.9
T
j
= +12 °C
Pdh
kW
7.7
9.9
T
j
= bivalent temperature
Pdh
kW
6.3
8.8
T
j
= operation limit temperature
Pdh
kW
6.3
8.8
Bivalent temperature
T
biv
°C
-10
-10
Cdh
-
1.0
1.0
Seasonal space heating energy efficiency under average conditions
ƞ
s
%
125
121
Seasonal space heating energy efficiency under colder conditions
ƞ
s
%
113
113
Seasonal space heating energy efficiency under warmer conditions
ƞ
s
%
167
161
Declared coefficient of performance or primary energy ratio for part
load at an indoor temperature of 20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
-
1.82
1.85
T
j
= +2 °C
COPd
-
3.17
3.02
T
j
= +7 °C
COPd
-
4.54
4.34
T
j
= +12 °C
COPd
-
6.19
5.75
T
j
= bivalent temperature
COPd
-
1.20
1.35
T
j
= operation limit temperature
COPd
-
1.20
1.35
Operation limit temperature for air-to-water heat pumps
TOL
°C
-10
-10
Heating water operating limit temperature
WTOL
°C
60
60
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.035
Stand-by
P
SB
kW
0.021
0.021
Crankcase heater mode
P
CK
kW
0.055
0.055
Supplementary heater
Rated heat output
Psup
kW
0.0
0.0
3 Technical specifications
12
MIT-S