Product name
MIV-4S V200
AWHP 4.5 MR
MIV-4S V200
AWHP 6 MR-3
MIV-4S V200
AWHP 8 MR-2
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
49 – 61
49 – 62
49 – 67
Annual energy consumption under average con
ditions
Q
HE
kWh
2353
2124
3499
Annual energy consumption under colder condi
tions
Q
HE
kWh
4483
3721
4621
Annual energy consumption under warmer condi
tions
Q
HE
kWh
1249
1492
1904
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
2100
2100
3300
Declared load profile
L
L
L
Daily electricity consumption
Q
elec
kWh
4,020
4,816
4,816
Annual electricity consumption
AEC
kWh
845
968
968
Water heating energy efficiency
ƞ
wh
%
121,00
106,00
106,00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
0
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is
equal to the supplementary capacity for heating
sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
Tab.12 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
MIV-4S V200
AWHP 11 MR-2
AWHP 11 TR-2
MIV-4S V200
AWHP 16 MR-2
AWHP 16 TR-2
Air-to-water heat pump
Yes
Yes
Water-to-water heat pump
No
No
Brine-to-water heat pump
No
No
Low-temperature heat pump
No
No
Equipped with a supplementary heater
Yes
Yes
Heat pump combination heater
Yes
Yes
Rated heat output under average conditions
(1)
Prated
kW
6
9
Rated heat output under colder conditions
Prated
kW
4
7
Rated heat output under warmer conditions
Prated
kW
8
13
Declared capacity for heating for part load at an in
door temperature of 20°C and outdoor temperature
T
j
T
j
= -7°C
Pdh
kW
5.9
9.0
T
j
= +2°C
Pdh
kW
5.3
6.5
T
j
= +7°C
Pdh
kW
9.0
12.9
T
j
= +12°C
Pdh
kW
7.7
10.0
T
j
= bivalent temperature
Pdh
kW
6.3
8.8
T
j
= operation limit temperature
Pdh
kW
6.3
8.8
Bivalent temperature
T
biv
°C
-10
-10
Degradation coefficient
(2)
Cdh
—
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
125
121
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
113
113
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
167
161
Declared coefficient of performance or primary en
ergy ratio for part load at an indoor temperature of
20°C and outdoor temperature
T
j
3 Technical specifications
16
MIV-4S V200
7682822 - v03 - 27082018