MIV-4

AWHP 8 MR-2

MIV-4

AWHP 11 

MR-2 

MIV-4

AWHP 16 

MR-2 

Water heating energy efficiency class under average climate 

conditions

 

A

A

A

Rated heat output under average climate conditions 

(Prated or 

Psup)

kW

6

6

8

Space heating - Annual energy consumption under average cli­

mate conditions

kWh

GJ

(1)

3316

3783

5184

Water heating - Annual energy consumption under average cli­

mate conditions

kWh

GJ

(1)

968

968

968

Seasonal space heating energy efficiency under average cli­

mate conditions

%

136

132

130

Water heating energy efficiency under average climate condi­

tions

%

106.00

106.00

106.00

Sound power level L

WA

 indoors

(2)

dB

48

47

47

Ability to off-peak hours functioning

(2)

 

No

No

No

Rated heat output, under colder - warmer climate conditions

kW

6 – 6

4 – 8

7 – 13

Space heating - Annual energy consumption, under colder - 

warmer climate conditions

kWh

GJ

(1)

4621 – 1904

3804 – 2580

5684 – 4120

Water heating - Annual energy consumption, under colder - 

warmer climate conditions

kWh

(3)

GJ

(1)(4)

1432 – 664

1432 – 664

1432 – 664

Seasonal space heating energy efficiency, under colder - warm­

er climate conditions

%

119 – 169

113 – 167

113 – 161

Water heating energy efficiency, under colder - warmer climate 

conditions

%

72.00 – 

154.00

72.00 – 

154.00

72.00 – 

154.00

Sound power level L

WA

 outdoors

dB

66

69

69

(1) For gas heat pumps only

(2) If applicable.

(3) Electricity

(4) Fuel

See

For specific precautions on assembly, installation and mainte­

nance: see the chapter on Safety Instructions.

13.2  Product fiche - Temperature Controls

Tab.37 Product fiche for the Temperature controls

 

 

IniControl 2

Class

 

II

Contribution to space heating energy efficiency

%

2

13.3  Package fiche

Note

‘Medium-temperature application’ means an application where the 

heat pump space heater or heat pump combination heater deliv­

ers its declared capacity for heating at an indoor heat exchanger 

outlet temperature of 55°C.

13 Appendix

7623755 - v05 - 27042017

MIV-4

61

Summary of Contents for ALEZIO EVOLUTION EASYLIFE AWHP 11 MR-2

Page 1: ...EASYLIFE 3 ALEZIO EVOLUTION Ireland en User Manual Reversible air water Split Inverter heat pump ALEZIO EVOLUTION AWHP V200 MIV 4 E 4 8 V200 MIV 4 E 11 16 V200 MIV 4 H 4 8 V200 MIV 4 H 11 16 V200...

Page 2: ...sing the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer...

Page 3: ...1 Description of the keys 27 4 4 2 Description of the display 27 5 Operation 30 5 1 Use of the control panel 30 5 1 1 Browsing in the menus 30 5 2 Start up 30 5 3 Shutdown 31 5 3 1 Switching off the...

Page 4: ...1 Decommissioning procedure 56 10 Disposal 57 10 1 Disposal and Recycling 57 11 Environmental 58 11 1 Energy savings 58 12 Warranty 59 12 1 General 59 12 2 Terms of warranty 59 13 Appendix 60 13 1 Pr...

Page 5: ...sional in accordance with prevail ing local and national regulations Warning Do not touch the refrigeration connection pipes with your bare hands while the heat pump is run ning Danger of burn or fros...

Page 6: ...r Note Allow the space required to install the appliance correctly refer to the chapter Dimensions of the Appliance Installation and Service Manual Caution Refrigerant safety Danger In the event of a...

Page 7: ...t point refer to the chapter Setting the domestic hot water temperature set point Caution Pressure limiter device refer to the chapter Spe cial precautions to be taken when connecting the domestic hot...

Page 8: ...the wiring according to the wiring schematics described in the chapter Electrical Connections Installation and Service Manual Caution This appliance must be connected to the protec tive earth Earthin...

Page 9: ...ssionals may carry out electri cal connections always with the power off Caution Separate the very low voltage cables from the 230 400 V circuit cables Note The frost protection function does not work...

Page 10: ...water and pres sure in the heating installation Important Keep this document close to the place where the appliance is installed Caution Do not make any modifications to the heat pump without the wri...

Page 11: ...id R410A Hazard identification Effects harmful to health The vapours are heavier than air and may lead to as phyxia owing to reduced oxygen levels Liquefied gas contact with the liquid may cause seri...

Page 12: ...ixture may form under certain temperature and pressure conditions Toxic and corrosive vapours may be released by the effect of the heat Special intervention methods cool the volumes exposed to heat wi...

Page 13: ...egulation EC No 842 2006 1 4 Liabilities 1 4 1 Manufacturer s liability Our products are manufactured in compliance with the requirements of the various Directives applicable They are therefore delive...

Page 14: ...optimum operation of the system you must abide by the following instructions Read and follow the instructions given in the manuals provided with the appliance Call on a qualified professional to carr...

Page 15: ...other manuals or pages in this manual 2 2 2 Symbols used on the appliance 1 Alternating current 2 Protective earthing 1 Information on the heat pump type of refrigerant fluid maximum operating pressur...

Page 16: ...h hydraulic back up 10 Return from boiler back up only for versions with hydraulic back up 11 Domestic cold water inlet 12 Drain valve 13 Safety valve 14 3 8 refrigerant fluid connection liquid line 1...

Page 17: ...me of installation shall apply to all regulations and guidelines speci fied in this manual 3 2 Technical data 3 2 1 Heat pump Maximum operating pressure 0 3 MPa 3 bar Tab 3 Conditions of use Water C O...

Page 18: ...2 06 3 19 3 19 3 94 3 94 Tab 6 Cooling mode outside air temperature 35 C water temperature at the outlet 18 C Performances in accordance with EN 14511 2 Measure ment type Unit AWHP 4 MR AWHP 4 5 MR AW...

Page 19: ...10 1 Noise radiated by the envelope Test run in accordance with the NF EN 12102 standard temperature conditions air 7 C water 55 C 2 Noise radiated by the envelope Test run in accordance with the NF E...

Page 20: ...2 AWHP 16 TR 2 Loading time 1 1 hour 54 mi nutes 1 hour 40 mi nutes 2 hours 2 hours 11 mi nutes 1 hour 33 mi nutes 1 hour 11 mi nutes Coefficient of performance domestic hot water COPDHW 2 72 3 00 2...

Page 21: ...j 7 C Pdh kW 4 0 4 5 4 8 Tj 12 C Pdh kW 4 2 5 5 5 2 Tj bivalent temperature Pdh kW 2 0 3 9 3 6 Tj operation limit temperature Pdh kW 2 0 3 9 3 6 Bivalent temperature Tbiv C 10 10 10 Degradation coeffi...

Page 22: ...cy wh 106 00 121 00 106 00 Daily fuel consumption Qfuel kWh 0 000 0 000 0 000 Annual fuel consumption AFC GJ 0 0 0 1 The rated heat output Prated is equal to the design load for heating Pdesignh and t...

Page 23: ...2 C COPd 3 49 3 43 3 33 Tj 7 C COPd 4 57 4 54 4 34 Tj 12 C COPd 6 33 6 24 5 82 Tj bivalent temperature COPd 1 63 1 45 1 54 Tj operation limit temperature COPd 1 63 1 45 1 54 Operation limit temperatu...

Page 24: ...wh 106 00 106 00 106 00 Daily fuel consumption Qfuel kWh 0 000 0 000 0 000 Annual fuel consumption AFC GJ 0 0 0 1 The rated heat output Prated is equal to the design load for heating Pdesignh and the...

Page 25: ...welded in side the tank made of smooth piping Its external surface which comes into contact with drinking water is enamelled The domestic hot water tank is insulated by Chlorofluorocarbon free pol yur...

Page 26: ...plate exchanger in the indoor module 4 Electronic expansion valve 5 Electrical energy 6 Heating water 7 Energy flow 8 Heat recovered from the environment 4 3 Main components 1 Control panel access fla...

Page 27: ...back up in demand Electrical back up Stage 1 of the electrical back up Stage 2 of the electrical back up Status of the Compressor Steady symbol compressing running Operating modes Steady symbol heatin...

Page 28: ...g menu the appliance runs at the set point dis played the pumps operate and the three way valves are not con trolled Malfunction menu the appliance has malfunctioned This informa tion is signalled by...

Page 29: ...ay Timer program for Sunday CLOCK sub menu CLK Temperature sensors Room temperature sensor connected fixed symbol for WINTER mode flashing symbol for SUMMER mode Outside temperature sensor connected f...

Page 30: ...cons flash Press the key to access the next menu access the next sub menu access the next parameter increase the value Press the key to access the previous menu access the previous sub menu access the...

Page 31: ...key 3 Confirm by pressing the key 4 Select the heating shut down pressing the key The screen displays The frost protection function continues to run The heating has been shut down Note Press the key...

Page 32: ...screen will display 5 Confirm by pressing the key 6 Go back to the main display by pressing the h key Note The display disappears after a few seconds of inactivity 5 3 3 Shutting down the cooling func...

Page 33: ...ature is lower than 3 C the back up starts up If the water temperature is higher than 10 C the back up shuts down and the circulating pump continues to run for a short time The radiator valves in room...

Page 34: ...meters Heating circuit parameters Tab 17 List of parameters in the sub menus of the User menu Parameter Description Factory setting Factory setting Post operation time of the circuit pump Can be set f...

Page 35: ...not modify this setting 0 0 Note DP Direct Hot Water Parameters Domestic hot water tank pa rameters Tab 18 List of parameters in the sub menu of the User menu Parameter Description Factory setting Num...

Page 36: ...arameters Heat pump parameters Tab 20 List of to parameters in the sub menu of the User menu Parameter Description Factory setting Cost of peak time electricity Can be set from 0 01 to 2 50 kWh 0 13 k...

Page 37: ...22 List of sub menus Sub menu Description COUNTERS Timer programming for the main heating circuit Timer programming for the additional heating circuit B Timer programming for the domestic hot water ci...

Page 38: ...X Number of pump start ups X Number of hours operation of back up 1 hours X Number of hours operation of back up 2 hours X Number of start ups of back up 1 X Number of start ups of back up 2 X Number...

Page 39: ...parameters 5 Confirm the selection by pressing the key 6 Modify the value of the parameter using the or keys 7 Confirm the new value of the parameter by pressing the key 8 Go back to the main display...

Page 40: ...ers by pressing the key 2 Modify the domestic hot water set point by pressing the or key Note Press the h key to cancel all input 3 Confirm the new temperature set point by pressing the key Go back to...

Page 41: ...he Manual Forcing menu Important The Manual Forcing menu is only available when the icon flash es 2 Set the value of the heating water temperature set point by pressing the or keys 3 Confirm the new v...

Page 42: ...ing for the cooling by pressing the or key 4 Confirm the selection by pressing the key The icons dedicated to the days of the week all flash at the same time 5 Select the desired day number by pressin...

Page 43: ...he main display by pressing the h key Example Times 06 00 22 00 06 00 22 00 06 00 08 00 11 30 13 30 06 00 08 00 11 30 13 30 06 00 08 00 11 30 14 00 17 30 22 00 06 00 08 00 11 30 14 00 17 30 22 00 6 3...

Page 44: ...re in the heating sys tem bar X Outside temperature C X X Flow rate in the system l min X Season mode 0 winter frost protection 1 winter 2 summer deadband 3 summer X Temperature set point X Room tempe...

Page 45: ...meter version X X 6 3 1 Control system sequence Tab 31 List of statuses and sub statuses Status parameter Sub status parameter off total system shut down heating cooling domestic hot water demand off...

Page 46: ...et point limited If the heating set point on the heat pump differs from the system set point pump post operation Heat pump and back up shut down system pump operation compressor bypass The back ups ar...

Page 47: ...ng temperature Compressor shut down blockage normal operation The compressor or the back ups are running internal set point limited If the heating set point on the heat pump differs from the system se...

Page 48: ...ressor has stopped The back ups are operating defrosting running The compressor and the back ups are running frost protection normal operation The compressor or the back ups are running internal set p...

Page 49: ...erating tem perature The compressor has stopped The back ups are operating the outside temperature is lower than the compressor s maximum op erating temperature The compressor has stopped The back ups...

Page 50: ...7 1 1 Troubleshooting Caution All work on the refrigeration circuit must be done by a qualified professional according to prevailing codes of practice and safety in the profession recovery of the ref...

Page 51: ...7 3 Cleaning the casing 1 Clean the outside of the appliance using a damp cloth and a mild detergent 7 Maintenance 7623755 v05 27042017 MIV 4 51...

Page 52: ...01 SENS T FLOW CLOSED Hybrid system flow sensor defective H00 16 SENS DHW OPEN Domestic hot water sensor not connected H00 17 SENS DHW CLOSED Domestic hot water sensor not connected H00 32 SENS T OUTS...

Page 53: ...ve been eliminated by the installer When one of the following codes is displayed and the heat pump cannot restart automatically contact a maintenance technician Tab 33 List of fault codes Fault code M...

Page 54: ...ey the parameter flashes after the errors cor responds to the PCB selected Clear the error log by pressing the key 7 Exit the Malfunctions menu by pressing the h key 8 3 Troubleshooting Problems Proba...

Page 55: ...s connec ted increase the temperature on it The heat pump is not op erating Check that the heat pump is switched on Check the fuses and switches on the electrical installation The water pressure is to...

Page 56: ...9 Decommissioning 9 1 Decommissioning procedure To decommission the heat pump temporarily or permanently 1 Contact the installer 9 Decommissioning 56 MIV 4 7623755 v05 27042017...

Page 57: ...cling Warning Removal and disposal of the heat pump must be carried out by a qualified professional in accordance with prevailing local and na tional regulations Fig 55 Recycling MW 3000179 03 10 Disp...

Page 58: ...ls behind the radiators to prevent heat losses Insulate the pipes in rooms that are not heated cellars and lofts Close the radiators in rooms not in use Do not run hot or cold water pointlessly Instal...

Page 59: ...liable for material damage intangible los ses or physical injury resulting from an installation that does not comply with Legal or regulatory requirements or provisions laid down by the local au thori...

Page 60: ...nd power level LWA indoors 2 dB 49 49 48 Ability to off peak hours functioning 2 No No No Rated heat output under colder warmer climate conditions kW 2 3 5 4 4 5 Space heating Annual energy consumptio...

Page 61: ...1 4621 1904 3804 2580 5684 4120 Water heating Annual energy consumption under colder warmer climate conditions kWh 3 GJ 1 4 1432 664 1432 664 1432 664 Seasonal space heating energy efficiency under c...

Page 62: ...2 Class III 1 5 Class IV 2 Class V 3 Class VI 4 Class VII 3 5 Class VIII 5 Temperature control Seasonal space heating energy efficiency of heat pump 1 If tank rating is above A use 0 95 from fiche of...

Page 63: ...02 0 0 7 0 0 1 The intermediate values are calculated by linear interpolation between the two adjacent values 2 Prated is related to the preferential space heater or combination heater Tab 39 Package...

Page 64: ...energy efficiency of package under average climate Auxiliary electricity Solar contribution Water heating energy efficiency of combination heater from fiche of solar device Colder Warmer Water heatin...

Page 65: ...13 Appendix 7623755 v05 27042017 MIV 4 65...

Page 66: ...13 Appendix 66 MIV 4 7623755 v05 27042017...

Page 67: ...nological information contained in these technical instructions as well as any drawings and technical de scriptions supplied remain our property and shall not be multiplied without our prior consent i...

Page 68: ...0 56 130 00 Praha 3 49 0 25 72 9161 0 49 0 25 72 9161 102 info remeha de Via Passatore 12 12010 San Defendente di Cervasca CUNEO 39 0171 857170 39 0171 687875 info duediclima it 420 271 001 627 dediet...

Reviews: