Dedicated Micros ©2007
Domes
Recess Mount Installation
Refer to the Quickstart section for more information.
1
To recess mount the camera, the shroud must be removed. Gently squeeze
together opposite sides of the shroud as shown and lift it away from the camera
body.
2
Using the template supplied at the rear of this manual, mark and cut a 4” (100 mm)
diameter hole. A suitably sized hole saw can also be used.
To prepare for installation use a suitable screwdriver to loosen the three fixing
clamps sufficiently to accommodate the thickness of the tile or ceiling.
3
Connect the video to either the BNC at the end of the flying lead or directly to the
BNC. Use only one of the BNC connectors to connect video.
Connect the power to the power terminals. These cameras are designed to operate
from a 12V DC or 24V AC power supply. Connections and polarity are indicated
next to the terminals. The power supply must be a UL Listed, Class 2 isolated type.
4
Insert the camera into the hole. Using a suitable screwdriver, tighten the three fixing
clamps as shown. Do not overtighten the clamps.
Camera Adjustment
Camera Position
The camera assembly is adjustable in all three axes. Adjust the camera until it is pointing in the
desired direction.
FOV & Focus
Use the levers on the varifocal lens to adjust the camera’s field of view, and focus.