ANPR

Camera Care

In order to avoid damaging your camera, note the following points:

CAUTION

•  Service the camera in a clean, dry, dust-free environment.
•  Remove all packaging inserts and any protective film from the camera before use.
•  Installation should be made by a qualified service person and should conform to all local codes.
•  Do not touch the image surface of the sensor. If the sensor is accidentally touched, only clean it 

using isopropanol.

•  To reduce a risk of unit failure, fire or electric shock, do not expose the interior of this product to 

rain or moisture.

CE NOTICE (EUROPEAN UNION).

Marking by the symbol CE indicates compliance of this DM product to the Electromagnetic 

Compatibility Directive 89/336/EEC, and the Low Voltage Directive 73/23/EEC of the European 

Union. Such marking is indicative that this system meets the following technical standards.

•  EN 61000-6-3 EMC Standard Residential, Commercial and Light Industry.
•  EN 61000-3-3 Limitations of voltage changes, fluctuations and flicker in public low-voltage supply 

systems for equipment with rated current up to 16A.

•  EN 61000-3-2 Limits for harmonic current emissions for equipment with rated current up to 16A.
•  EN 50130-4 Immunity requirements for components of fire, intruder and social alarm systems.
•  EN 60950 Safety of IT and related equipment.
•  EN 55022 Class B. Radiated Emissions Standard, suitable for Commercial or Residential use.
•  EN 60825-1 Safety standard for LED’s and Lasers.
Further details about these applicable standards can be obtained from Dedicated Micros Ltd. 1200 

Daresbury Park, Daresbury, Cheshire, WA44HS.
A “Declaration of Conformity” with all relevant European Union Directives has been made, is on file 

and is available from the Dedicated Micros address above.
This product is marked with the CE symbol and indicates compliance with all applicable directives.
Directive 89/336/EEC.
A “Declaration of Conformity” is held at Dedicated Micros Ltd., 1200 Daresbury Park, Daresbury, 

Cheshire, WA44HS.

Summary of Contents for HyperSense

Page 1: ...HyperSense ANPR Camera Installation Manual www dedicatedmicros com...

Page 2: ...scribed herein without prejudice Contents Introduction 3 Components supplied 6 Installing the Camera 7 Mounting 9 Electrical Connections 10 Adjusting FOV and Focus 11 Configuring the Unit Intelligent...

Page 3: ...dditional overview camera fitted would be used for recording images of the vehicle for verification or evidential purposes whilst CamVu versions of the HyperSense camera can be configured to carry out...

Page 4: ...interference and 2 this device must accept any interference received including interference that may cause undesired This equipment has been tested and found to comply with the limits for a Class B di...

Page 5: ...EMC Standard Residential Commercial and Light Industry EN 61000 3 3 Limitations of voltage changes fluctuations and flicker in public low voltage supply systems for equipment with rated current up to...

Page 6: ...ponents Supplied 1 x DM HyperSense ANPR Camera IP66 housing with pre wired cabling 1 x DM HyperSense ANPR Manual 1 x 3mm A F Allen Key 1 x 5mm A F Allen Key 1 x Spanner Additional components for analo...

Page 7: ...ling the camera ensure that it can capture the whole plate taking into account vehicles which may have their number plates positioned off centre To assist in directing any vehicles into the field of v...

Page 8: ...ely identified This could lead to chaos at the entrance to a car park with an ANPR controlled barrier each rush hour Contingencies for such scenarios must be identified developed and be made available...

Page 9: ...efore mounting on wall Use appropriate wall fixings to support the housing and camera B B B B To convert the housing from wall mounted to ceiling mounted orientation Remove 2 off fixings C rotate brac...

Page 10: ...s Cat5 cable with single RJ45 plug Power Cable for installer termination into appropriate 12VDC 1A 24VAC 500mA PSU NOTE The HyperSense ANPR camera housing must be earthed by connecting the earth wire...

Page 11: ...e housing needs to be opened to access the adjustment levers The following procedure should be followed 1 Remove the 6 off M5 x 20 socket head screws from the back plate using a 4mm A F long series ba...

Page 12: ...network and a PC or laptop connected to the same network running NetVu ObserVer to enable fine focus Models that incorporate the overview camera can be adjusted by setting the overview image and then...

Page 13: ...l attempt to contact the DHCP server every time it starts up If for any reason a DHCP server cannot allocate an IP address to the unit the camera will use a default IP address 169 254 6 10 Note Always...

Page 14: ...Mozilla Firefox 6 12 2 Type the IP address of the unit into the address bar 3 The first Menu page will be displayed 6 13 The other configuration menus are accessible via the links on the left hand si...

Page 15: ...allocated to the overview camera if fitted Note Camera 1 and Camera 2 Names will be recognised by any NetVu Connected device that views it ie NetVu ObserVer NetVu Console SD DV IP Range and HighVu and...

Page 16: ...nit was installed on a DHCP network this will display the IP address of the DHCP server allocated on power up of the unit DHCP Subnet If the unit was installed on a DHCP network this will be the subne...

Page 17: ...tely estimated This sets the limits at which the software will try and recognise a plate typically 10000 Min Plate size pixels Once the FOV and Focus have been set the Minimum plate size that can be d...

Page 18: ...r another This can be used to generate alarm events on the DVR and send a PTZ camera to a preset to record the entry Camera Preset This parameter is the preset on a PTZ camera to be associated with AN...

Page 19: ...ros 2008 19 ANPR Connections This page shows the IP addresses of machines currently connected to the camera via the network IP Addresses A list of up to four IP addresses connected to the camera will...

Page 20: ...Dedicated Micros 2008 20 ANPR Reset This page allows the camera to be restarted remotely Reset System...

Page 21: ...Dedicated Micros 2008 21 ANPR Camera Dimensions Overall Dimensions All dimensions in millimetres 230 150 140 332 451 95 Mounting Template 6 5 50 8 19 95 95 6 5 23 5...

Page 22: ...ipaddress replacing ipaddress with the ip address of the unit From the same dos prompt Type dm at the username prompt Type telnet at the password prompt Type devcopy a web zip flash web zip Type CW0 d...

Page 23: ...dows click on Start Run and type cmd in the dialog box that opens then click OK This opens up a dos window Type cd to get to the c prompt Type cd c hypersense or insert the local folder holding the do...

Page 24: ...camera is as follows 1 5 6 9 RS232 Connectivity Pin Description Desc 1 Data Carrier Detect DCD 2 Receive Data RX 3 Transmit Data TX 4 Data Terminal Ready DTR 5 Ground GND 6 Data Set Ready DSR 7 Ready...

Page 25: ...Dedicated Micros 2008 25 ANPR Notes...

Page 26: ...Dedicated Micros 2008 26 ANPR Notes...

Page 27: ...P 23 Installing the Camera 7 Intelligent IP Analogue ANPR with Overview Camera connections 10 Intelligent IP ANPR Camera connections 10 Intelligent IP Camera 10 Introduction 3 Locating the unit IP add...

Page 28: ...nt Place Suite 100 Chantilly Virginia 20151 USA Dedicated Micros Australia PTY 5 3 Packard Avenue Castle Hill NSW 2154 Australia Dedicated Micros Asia PTY 16 New Industrial Road 03 03 Hudson Techno Ce...

Reviews: