![Dedicated Micros Dennard 2025 Installation Manual Download Page 13](http://html1.mh-extra.com/html/dedicated-micros/dennard-2025/dennard-2025_installation-manual_2462350013.webp)
Fig. 8
- Mains Cable Preparation
11. Configuration
Power Settings
It is possible to configure the supply at 4 different power levels. The factory setting is high power.
If using the lamp at temperatures above 40°C or using continuously it is recommended that you use
Medium power or lower to maximise the life of the LEDs.
Switch 1 and 10 in the switch bank control the power level settings. The factory default setting is
high power.
Dennard 2025
Installation Manual
Page.
11
CONNECTION TO DENNARD 2025 PSU
6mm STRIP AND
PREP FOR
TERMINAL
BLOCK
GREEN/YELLOW
EARTH
BLUE - NEUTRAL
BROWN -
LIVE
4-6mm OUTER
INSULATION DIAMETER
24mm MIN
20mm MAX OUTER
INSULATION REMOVED
CONNECTION TO CUSTOMER WIRING
BROWN - LIVE
GREEN/YELLOW
EARTH
BLUE - NEUTRAL
Switch 1
Switch 10
Power mode
ON
ON
Ultra low
ON
OFF
Low
OFF
ON
Medium
OFF
OFF
High