background image

4 no. 12 x 1 ½’’ wood screws (no.4).  You will need two people to move the fireplace (no.5) into 

position, place it onto the hooks of the horizontal support (no.1) by matching up the hooks with 

the square holes at the back of the unit.

Make sure that the fireplace is level.

Attach the 2 vertical supports (no.3) at the base of the fireplace (no.5) with 2 self-tapping 

screws (no.6).

Place the burner support (no.7) into the fireplace opening.

Insert the reservoir (no.8) into the burner support (no.7).

Place the damper (no.9) onto the top of the bioethanol reservoir (no.8).

Using the designated holes install the window panes (no. 10)onto the front of the fireplace.  

Ensure that they open and close correctly.

BURNER

Filling capacity: our model has a capacity of 1 litre and a tank of 15% flood (.150 litre).  Which 

gives 2.75 hours burning capacity when the damper is completely open.  You can increase the 

length to 5 hours by reducing the flames’ height by simply moving the damper forward.  The 

burner elements are removable and must be installed in the fireplace according to the instruc-

tions before ignition. The fuel must be poured into the burner reservoir. 

If any spatters occur, make sure to clean them before lighting the fire.

COMBUSTIBLE FUEL

Only use 

« 

deco

fuel

 

» 

liquid fuel.

CAUTION

:  DO  NOT  USE  PAPER,  NEWSPAPERS,  STRAW,  KINDLING  WOOD  OR  ANY  OTHER 

FLAMMABLE PRODUCT TO START THE FIRE.

The  combustible  fuel  is  a  highly  flammable  product.    It  should  be  kept  away  from  any  heat 

sources.  Never place in direct sunlight.  Do not store or carry fuel in a plastic or metal container 

that is not designated for this purpose.  Never store fuel in the same location as the fireplace.  

Keep it in a safe place and keep it away from children.

In case of ingestion, inhalation and/or contact with eyes or skin, urgently contact the poison 

control centre or consult a Doctor.

Summary of Contents for ARC 103A

Page 1: ... Wall Mounted Fireplace Models ARC 103A VAGUE 101A CONTENTS Safety instructions p 2 Wall mounted fireplace installation p 3 Burner installation p 3 Burner p 3 Combustible Fuel p 4 Instructions p 4 General rules Filling Lighting Extinguishing While using Cleaning the burner p 5 Cleaning the fireplace p 5 Warranty p 6 ...

Page 2: ...ace is for decorative purposes only and not to be used as your main heat source Keep children and pets away while operating the fireplace especially while lighting it up Caution If your wall is covered with wallpaper wood varnish or other flammable material you must use a fire proof backing on the wall Any furniture curtains or other flammable materials must be located at a safe and secure dis tan...

Page 3: ...decorative fire place is functioning or still hot Do not fill the fuel reservoir completely and use the adjustable pourer to do so If the deco fuel fuel spills out of the reservoir wipe it with an absorbent paper before lighting Continually monitor the device as soon as the fire is started The steel elements of the fireplace can become very hot while the combustible fuel is burning Never touch the...

Page 4: ...appliance should not be used in a small room where less than 5 7 m3 200 ft3 of air space is provided for each 1000 Btu per hour of the unvented decorative device rating considering the maximum burner adjustment Do not use the unvented decorative fireplace in a bathroom a room where sleeping accommodation is provided or any other small room Make sure that the shut off device works properly before l...

Page 5: ...acity when the damper is completely open You can increase the length to 5 hours by reducing the flames height by simply moving the damper forward The burner elements are removable and must be installed in the fireplace according to the instruc tions before ignition The fuel must be poured into the burner reservoir If any spatters occur make sure to clean them before lighting the fire COMBUSTIBLE F...

Page 6: ...vel indicator maximum of 1 5 Litres Do not overflow or splash around the reservoir If any spatters occur clean them with a rag or a paper towel in order to absorb the excess Do not throw this rag or paper towel in the garbage let it dry and keep it away from the fire children and pets then dispose of it Only use decofuel fuel LIGHTING The damper must be completely open The fuel must be kept at roo...

Page 7: ...fireplace or the burner while it is in operation serious burns may occur EXTINGUISHING Keep the glass doors closed Pull the damper completely closed WHILE USING Constantly monitor the device as soon as the fire has been started Have a class B fire extinction device nearby In case of a burn call the nearest hospital Consult a Doctor if in doubt of any severe burn Igniting the fireplace implies that...

Page 8: ...n material or workmanship and commits to reparing or replacing at decoflame s dis cretion any defective product free of charge within 2 years from the date of purchase A proof of purchase such as a dated sales receipt sales slip etc indicating the model and serial number will be required before any intervention from our dealers will be made on the guaranteed product You are obligated to meet the d...

Page 9: ...INSTALLATION OF THE WALL MOUNTED FIREPLACE AND BURNER ARC 103A ...

Page 10: ...INSTALLATION OF THE WALL MOUNTED FIREPLACE AND BURNER VAGUE 101A ...