background image

Never light the combustible fuel in a burner that is not properly positioned. 

Only use 

« 

deco

fuel

 

» 

 combustible fuel in your fireplace.

Never use any fuel other than the fuel specifically identified for use in an unvented decorative 

device.  Never use gasoline, solvents, methylated or burning alcohol, thinner, ethanol gel, etc. 

The use of an ethanol gel is strictly 

prohibited

 since this will render your tank unusable.

Do not combine any other fuel to the 

« 

deco

fuel

 

» 

fuel. 

Do not smoke while handling the combustible fuel.

Light the burner with the lighting rod.  Holding the lighting rod away from you slightly soak the 

end of the rod in the 

« 

deco

fuel

 

»

 fuel in order to use it as a lighting device.  Light the rod with 

a lighter (view illustration in 

appendix

).

Do not use paper or newspaper to start the fire. 

Never add fuel if the fireplace is partially or fully in operation.

Never refill the unvented decorative fireplace fuel reservoir when the unvented decorative fire-

place is functioning or still hot.

Do not fill the fuel reservoir completely and use the 

adjustable pourer to do so

.  If the 

« 

deco-

fuel

 

»

 fuel spills out of the reservoir, wipe it with an absorbent paper before lighting.

Continually monitor the device as soon as the fire is started.

The steel elements of the fireplace can become very hot while the combustible fuel is burning.  

Never touch these elements while the fireplace is in operation, even several minutes after it is 

turned off. 

Do not move the fireplace while it is lit.

Avoid drafts

.

This device was subjected to tests for its use with glass doors. To reduce fire hazard or injury, 

never remove the doors.

Do not use additional parts or other products that are not designated for use with this fireplace.

The combustible fuel is a highly flammable product. 

Never store or transport the fuel in anything other than a metal or plastic container that is ac-

ceptable for use with the specified fuel in accordance with the Consumer Chemicals and Con-

tainers Regulations 2001 and is the original container for the specified fuel.

Never store fuel in the same location as the appliance.

Summary of Contents for ARC 103A

Page 1: ... Wall Mounted Fireplace Models ARC 103A VAGUE 101A CONTENTS Safety instructions p 2 Wall mounted fireplace installation p 3 Burner installation p 3 Burner p 3 Combustible Fuel p 4 Instructions p 4 General rules Filling Lighting Extinguishing While using Cleaning the burner p 5 Cleaning the fireplace p 5 Warranty p 6 ...

Page 2: ...ace is for decorative purposes only and not to be used as your main heat source Keep children and pets away while operating the fireplace especially while lighting it up Caution If your wall is covered with wallpaper wood varnish or other flammable material you must use a fire proof backing on the wall Any furniture curtains or other flammable materials must be located at a safe and secure dis tan...

Page 3: ...decorative fire place is functioning or still hot Do not fill the fuel reservoir completely and use the adjustable pourer to do so If the deco fuel fuel spills out of the reservoir wipe it with an absorbent paper before lighting Continually monitor the device as soon as the fire is started The steel elements of the fireplace can become very hot while the combustible fuel is burning Never touch the...

Page 4: ...appliance should not be used in a small room where less than 5 7 m3 200 ft3 of air space is provided for each 1000 Btu per hour of the unvented decorative device rating considering the maximum burner adjustment Do not use the unvented decorative fireplace in a bathroom a room where sleeping accommodation is provided or any other small room Make sure that the shut off device works properly before l...

Page 5: ...acity when the damper is completely open You can increase the length to 5 hours by reducing the flames height by simply moving the damper forward The burner elements are removable and must be installed in the fireplace according to the instruc tions before ignition The fuel must be poured into the burner reservoir If any spatters occur make sure to clean them before lighting the fire COMBUSTIBLE F...

Page 6: ...vel indicator maximum of 1 5 Litres Do not overflow or splash around the reservoir If any spatters occur clean them with a rag or a paper towel in order to absorb the excess Do not throw this rag or paper towel in the garbage let it dry and keep it away from the fire children and pets then dispose of it Only use decofuel fuel LIGHTING The damper must be completely open The fuel must be kept at roo...

Page 7: ...fireplace or the burner while it is in operation serious burns may occur EXTINGUISHING Keep the glass doors closed Pull the damper completely closed WHILE USING Constantly monitor the device as soon as the fire has been started Have a class B fire extinction device nearby In case of a burn call the nearest hospital Consult a Doctor if in doubt of any severe burn Igniting the fireplace implies that...

Page 8: ...n material or workmanship and commits to reparing or replacing at decoflame s dis cretion any defective product free of charge within 2 years from the date of purchase A proof of purchase such as a dated sales receipt sales slip etc indicating the model and serial number will be required before any intervention from our dealers will be made on the guaranteed product You are obligated to meet the d...

Page 9: ...INSTALLATION OF THE WALL MOUNTED FIREPLACE AND BURNER ARC 103A ...

Page 10: ...INSTALLATION OF THE WALL MOUNTED FIREPLACE AND BURNER VAGUE 101A ...

Reviews: