Flue Connections and Outlets
Flue Connections and Outlets
Dean Stoves can be flued from the top and the back, or with a vertical back box. Horizontal flue from
back of stove should not exceed 150mm.
.
Diagrams showing the flue outlet from the top (
A
), back (
B
) and back box (
C
)
All flue connections must be sealed with fire cement. Doors in the register plate must be present or a
soot box fitted in the back or side of the fireplace to enable access to clean the chimney when the stove
is installed without a liner.
If the chimney has been lined and cannot be swept through the stove an access door on the first length
of flue must be installed for cleaning access. When using a back box the correct Dartmoor baker back
box with a cleaning access must be use.
Leg Adjusters
To level the stove there are leg adjusters on each leg of the stove, a 13mm spanner will be required to
make any adjustment.